Skip to main content
Siemens 3VA2216-7MS32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-7MS32-0AA0 SENTRON MCCB, 160 A, 3-pole, ETU3

MPN3VA2216-7MS32-0AA0
Active

Siemens SENTRON 3VA2216-7MS32-0AA0, molded case circuit breaker, 3-pole, 160 A, ETU310M electronic trip unit, 330 kA at 240 V AC.

$379.73Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2216-7MS32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2216-7MS32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.19.7 W
3VA2216-7MS32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2216-7MS32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2216-7MS32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2216-7MS32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2216-7MS32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2216-7MS32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 160 A continuous current across the entire ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. That flat thermal curve simplifies panel design: you don't have to oversize the frame for a hot enclosure. The interrupting ratings are the headline: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 4.5 kA at 690 V. The design is listed as starter protection, meaning the trip unit is configured for motor-starting inrush profiles — the ETU310M can be set to ride through the start transient without nuisance tripping. Maximum power loss is 19.7 W, which matters for thermal management inside a sealed or high-density panel.

That's a 4.13 by 7.13 by 3.39 inch envelope — fits most existing panel cutouts for 160 A frame breakers. The 3-pole design with no undervoltage release and no communication module keeps wiring simple: line and load lugs only, no auxiliary control power needed for the trip unit. The breaker has no trip indicator, no voltage trigger, no phase failure detection, and no ground-fault monitoring — it's a straight overcurrent protection device. If you need ground-fault or phase-loss protection, you add external modules or specify a different variant.

Frequently asked questions

Where can I buy 3VA2216-7MS32-0AA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the trip unit on this breaker?

ETU310M electronic trip unit — adjustable overload and short-circuit protection curves, designed for starter protection with motor-starting inrush profiles.

MPN
3VA2216-7MS32-0AA0