Skip to main content
Siemens 3VA2220-5MN32-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2220-5MN32-0CH0 SENTRON MCCB, 200A, 3-Pole, Motor

MPN3VA2220-5MN32-0CH0

Siemens SENTRON 3VA2220-5MN32-0CH0, 3-pole molded case circuit breaker, 200 A at 40-70 °C, motor protection design, breaking capacity 121 kA at 415 V, depth 86 mm, width 105 mm, height 181 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2220-5MN32-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2220-5MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2220-5MN32-0CH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C200 A
Current at 60 °C200 A
Current at 65 °C200 A
Current at 70 °C200 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V5.2 kA
Power loss, max.46 W
3VA2220-5MN32-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2220-5MN32-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2220-5MN32-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2220-5MN32-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2220-5MN32-0CH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Breaking capacity at 415 V is 121 kA, dropping to 75.6 kA at 500 V and 5.2 kA at 690 V. That 121 kA figure at common 400 V-class distribution voltages means it handles high-fault-current scenarios without the upstream breaker having to clear — useful for main or sub-feed positions in an industrial panel.

Motor protection specific — phase failure and undervoltage

This breaker is designed specifically for motor protection, with built-in phase failure detection. If one phase drops out — say a blown fuse or a loose connection on the line side — the breaker trips, keeping the motor from single-phasing and burning up. That's a real-world failure mode out here in the grease, and having it integrated saves adding a separate phase-loss relay. The UVR drops the breaker if the supply voltage sags below a set threshold, which is standard for applications where a motor must not re-accelerate unexpectedly after a brownout.

Integration dimensions

Footprint is 105 mm wide, 181 mm tall, and 86 mm deep — that's about 4.13 by 7.13 by 3.39 inches. It's a standard 3-pole MCCB form factor for panel mounting, not DIN-rail snap-on; expect to bolt it to a mounting plate and land lug kits or bus bars.

Frequently asked questions

Does the 3VA2220-5MN32-0CH0 include phase failure protection?

Yes, phase failure detection is built into the motor protection design — it trips on loss of any phase.

MPN
3VA2220-5MN32-0CH0