Skip to main content
Siemens 3VA2220-5MN32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2220-5MN32-0JA0 SENTRON MCCB, 200 A, 3P, Motor Pr

MPN3VA2220-5MN32-0JA0

Siemens SENTRON 3VA2220-5MN32-0JA0, molded case circuit breaker, 3-pole, 200 A rated continuous current, motor protection version with electronic ETU350M release, shunt trip, interrupting capacity 187 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2220-5MN32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2220-5MN32-0AA0
3VA2220-5MN32-0JA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C192 A
Current at 60 °C188 A
Current at 65 °C184 A
Current at 70 °C180 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.75 W
3VA2220-5MN32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
3VA2220-5MN32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2220-5MN32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2220-5MN32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2220-5MN32-0JA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

It carries a shunt trip release integrated as standard. Interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V, and 121 kA at 440 V, with 75.6 kA at 500 V and 17 kA at 690 V — enough for high-fault infrastructure panels where selectivity and SCCR headroom are non-negotiable.

The 200 A rated continuous current (Iu) holds across the entire 40 °C to 50 °C band without derating — at 55 °C it drops to 192 A, at 60 °C to 188 A, at 65 °C to 184 A, and at 70 °C to 180 A. The ETU350M electronic release gives adjustable thermal-magnetic curves and phase-failure detection, so it can be coordinated downstream of a larger SENTRON or upstream of a motor starter.

Panel Integration & Mounting

The 3-pole 200 A frame uses the same cutout and bus-bar spacing as other SENTRON 3VA2 breakers, so swapping a 160 A unit for this 200 A version requires no panel rework — just verify the bus-bar ampacity and the upstream fault rating.

Frequently asked questions

Who supplies 3VA2220-5MN32-0JA0 and how is it quoted for volume purchases?

It is sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

What is the interrupting capacity of this MCCB at 415 V?

121 kA at 415 V, and the same rating holds at 440 V.

What is the depth of 3VA2220-5MN32-0JA0?

86 mm depth, 105 mm width, 181 mm height.

MPN