Siemens SENTRON 3VA2 series, molded case circuit breaker (MCCB), 3VA2220-5MN32-0JC0, 200 A rated current at 40 °C, 3-pole, motor protection design, breaking capacity 187 kA at 240 V AC, 121 kA at 415 V AC, with shunt trip release and two auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2220-5MN32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2220-5MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2220-5MN32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C200 A
Current at 60 °C200 A
Current at 65 °C200 A
Current at 70 °C200 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V5.2 kA
Power loss, max.46 W
3VA2220-5MN32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2220-5MN32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2220-5MN32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2220-5MN32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2220-5MN32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Motor protection MCCB with phase failure detection and shunt trip

Breaking capacity is substantial: 187 kA at 240 V AC, 121 kA at 415 V AC and 440 V AC, tapering to 75.6 kA at 500 V AC and 5.2 kA at 690 V AC. That puts it in the high-interrupting category for industrial distribution — suitable for installations with high fault current potential, such as large motor control centers or transformer-fed switchboards. The basic switch variant is 3VA2220-5MN32-0AA0, so the -0JC0 suffix adds the shunt trip and auxiliary switch configuration.

The 105 mm width is typical for a 200 A frame in the SENTRON range, so panel cutouts and busbar spacing designed for other 3VA2 breakers of similar rating will accept this unit without modification.

Coordination and selectivity note

The motor protection design means the thermal-magnetic or electronic trip curve is shaped for motor starting inrush — the minimum trip time is 4 s, maximum 15 s, which accommodates typical NEMA Design B or IEC motor start profiles. Phase failure detection adds an extra layer of protection against single-phasing, which is a common cause of motor winding failure.

Frequently asked questions

Where can I buy 3VA2220-5MN32-0JC0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ with your quantity and target delivery window.

What is the breaking capacity of 3VA2220-5MN32-0JC0 at 415 V?

121 kA at 415 V AC, and the same rating at 440 V AC. At 240 V it is 187 kA, at 500 V it is 75.6 kA, and at 690 V it is 5.2 kA.

Does 3VA2220-5MN32-0JC0 include a shunt trip?

Yes, it includes a shunt trip release (STL) and two HQ auxiliary switches as standard from the factory.

What is the rated current of 3VA2220-5MN32-0JC0 at elevated temperatures?

200 A continuous from 40 °C through 70 °C — no derating required across that range.