Siemens 3VA2220-5MN32-0KA0 SENTRON MCCB, 200 A, 187 kA

MPN3VA2220-5MN32-0KA0

Siemens SENTRON 3VA2220-5MN32-0KA0, molded case circuit breaker, 3-pole, 200 A, 187 kA at 240 V, motor protection version, ETU350M electronic trip unit, shunt trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2220-5MN32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2220-5MN32-0AA0
3VA2220-5MN32-0KA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C192 A
Current at 60 °C188 A
Current at 65 °C184 A
Current at 70 °C180 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.75 W
3VA2220-5MN32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
3VA2220-5MN32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2220-5MN32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2220-5MN32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2220-5MN32-0KA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Motor protection MCCB with ETU350M — 200 A frame, 187 kA interrupting capacity

The Siemens SENTRON 3VA2220-5MN32-0KA0 is a 3-pole molded case circuit breaker (MCCB) in the motor protection version, rated for a continuous current Iu of 200 A and carrying an interrupting capacity of 187 kA at 240 V. The interrupting curve drops to 121 kA at 415 V and 440 V, then to 75.6 kA at 500 V, and 17 kA at 690 V, so the voltage class of your distribution system directly governs which rating applies. This MCCB uses the ETU350M electronic overcurrent release, which provides adjustable thermal-magnetic-like protection curves plus phase-failure detection. The phase-failure detection is a key differentiator for motor loads — it trips the breaker when one phase drops out, preventing single-phasing damage to the motor winding. The integrated auxiliary trip module is order code 3VA9688-0BL33; the basic switch is 3VA2220-5MN32-0AA0.

Above that it derates: 192 A at 55 °C, 188 A at 60 °C, 184 A at 65 °C, and 180 A at 70 °C. If the panel ambient inside your enclosure hits 55 °C — common in a packed MCC lineup — you lose 8 A of headroom. The maximum power loss is 75 W, which factors into enclosure ventilation sizing. Dimensions are 105 mm wide, 181 mm high, 86 mm deep — standard 3-pole MCCB footprint for the SENTRON 3VA platform, so it fits existing Siemens panel layouts and busbar systems without re-drilling.

As a Siemens SENTRON product, the 3VA2220-5MN32-0KA0 carries IEC 60947-2 certification for molded case circuit breakers, and is designed to meet UL 489 requirements for the North American market. The unit is RoHS and REACH compliant per Siemens standard declarations.

Frequently asked questions

How do I get current pricing and availability for 3VA2220-5MN32-0KA0?

We source this part through independent distribution and quote to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

Will 3VA2220-5MN32-0KA0 drop into a panel specified around 3VA1110-5EE32-0JA0 without rewiring?

No — the 3VA2220-5MN32-0KA0 is a 200 A frame with a 105 mm width, while the 3VA1110-5EE32-0JA0 is a smaller 100 A frame. The physical footprint and busbar spacing differ; a direct swap without panel modification is not possible.

What is the interrupting capacity of this MCCB at 415 V?

The interrupting capacity at 415 V is 121 kA. At 240 V it is 187 kA, at 440 V it is 121 kA, at 500 V it is 75.6 kA, and at 690 V it is 17 kA.

What compliance documentation does Siemens provide for 3VA2220-5MN32-0KA0?

Siemens provides IEC 60947-2 certification, UL 489 compliance, and RoHS/REACH declarations for the SENTRON 3VA series. The rated insulation voltage is 800 V.