Skip to main content
Siemens 3VA2225-0HN32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-0HN32-0AA0 SENTRON MCCB, 250 A, 3-Pole, ETU3

MPN3VA2225-0HN32-0AA0
Active

Siemens SENTRON 3VA2225-0HN32-0AA0, molded case circuit breaker, 3-pole, 250 A, ETU350 electronic trip unit, 440 kA at 415 V AC, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-0HN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2225-0HN32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.48 W
3VA2225-0HN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2225-0HN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-0HN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2225-0HN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-0HN32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2225-0HN32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current, designed for line protection in distribution panels and industrial switchgear. It carries a 440 kA breaking capacity at 415 V AC and 187 kA at 690 V AC, giving you serious fault-current headroom for high-capacity feeds.

Ratings that matter for fit

Rated 250 A continuous at 40 °C through 50 °C, then derates linearly to 213 A at 70 °C — so if your panel ambient runs hot, you lose about 15% capacity at the top end. The 800 V rated insulation voltage means it's comfortable on 480 V and 600 V class systems, and the 690 V operating voltage covers most industrial three-phase networks.

Dimensions: 181 mm high, 105 mm wide, 86 mm deep — fits most 3-pole MCCB footprints in existing SENTRON or third-party enclosures. No communication module, no undervoltage release, no auxiliary contacts on this order code — if you need those, you're looking at a different suffix.

Frequently asked questions

Where can I buy 3VA2225-0HN32-0AA0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of this MCCB at 415 V and 690 V?

440 kA at 415 V AC and 187 kA at 690 V AC — high enough for most main feeders and large transformer secondaries.

Does this breaker include ground-fault monitoring or communication?

No — this variant has no ground-fault monitoring, no communication module, no undervoltage release, and no auxiliary contacts. It is a straight line-protection MCCB with the ETU350 trip unit.

MPN
3VA2225-0HN32-0AA0