Skip to main content
Siemens 3VA2225-4JQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-4JQ42-0AA0 SENTRON MCCB, 250A 4P, ETU560

MPN3VA2225-4JQ42-0AA0

Siemens SENTRON molded case circuit breaker, 3VA2225-4JQ42-0AA0, 250 A, 4-pole, ETU560 electronic trip unit, 121 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2225-4JQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2225-4JQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V52.5 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W
3VA2225-4JQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
3VA2225-4JQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-4JQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2225-4JQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-4JQ42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

Siemens 3VA2225-4JQ42-0AA0 — 250 A SENTRON MCCB with ETU560 Trip Unit

It carries the ETU560 electronic trip unit, which supports adjustable N-conductor protection (OFF, 20% to 100%) and includes a communication function for integration into monitored distribution systems. Breaking capacity is specified across multiple voltage levels: 121 kA at 240 V, 75.6 kA at both 415 V and 440 V, 52.5 kA at 500 V, and 4.5 kA at 690 V. This selectivity profile suits it for main or branch feeder duty in low-voltage switchgear where high fault currents at lower voltages are expected.

Thermal Derating and Ambient Constraints

Above that, derating applies linearly: 238 A at 55 °C, 225 A at 60 °C, 213 A at 65 °C, and 200 A at 70 °C. For a panel OEM wireman, this means the breaker can be installed in a warm enclosure without immediate down-rating, provided the internal ambient stays at or below 50 °C. Above that, the load schedule must be adjusted. The IP40 front protection keeps debris and accidental contact out of the breaker face, but the body is not sealed against washdown — install in a dry location or a secondary enclosure.

Dimensions: 181 mm height, 140 mm width, 86 mm depth. The 140 mm width across four poles is the key panel-space constraint — standard for a 4-pole MCCB in this frame size. Depth of 86 mm leaves clearance for rear bus connections and wiring troughs in a typical 600 mm deep enclosure.

Frequently asked questions

What is the breaking capacity of 3VA2225-4JQ42-0AA0 at 240 V?

121 kA at 240 V. At 415 V and 440 V it is 75.6 kA, at 500 V it is 52.5 kA, and at 690 V it is 4.5 kA.

What trip unit does 3VA2225-4JQ42-0AA0 use?

It uses the ETU560 electronic trip unit, which provides adjustable N-conductor protection (OFF, 20% to 100%) and includes a communication function for remote monitoring.

Where can I buy 3VA2225-4JQ42-0AA0 and how is it quoted?

It is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

MPN
3VA2225-4JQ42-0AA0