Siemens 3VA2225-5HL32-0CL0 — Molded Case Circuit Breakers (MCCB)

3VA2225-5HL32-0CL0 SENTRON MCCB, 250 A, 3-pole, ETU320, 187

MPN3VA2225-5HL32-0CL0

Siemens SENTRON 3VA2225-5HL32-0CL0, Molded case circuit breaker, 3-pole, 250 A, Line protection, ETU320, 187 kA at 240 V, 121 kA at 415 V, 121 kA at 440 V, 79 kA at 500 V, 5.1 kA at 690 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-5HL32-0CL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2225-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2225-5HL32-0CL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V5.1 kA
Power loss, max.50.5 W
3VA2225-5HL32-0CL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2225-5HL32-0CL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-5HL32-0CL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2225-5HL32-0CL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-5HL32-0CL0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

SENTRON 3VA2225-5HL32-0CL0 — 250 A MCCB with ETU320 Release

It carries a maximum interrupting capacity of 187 kA at 240 V AC, derating to 121 kA at 415 V and 440 V, 79 kA at 500 V, and 5.1 kA at 690 V — the voltage-dependent curve governs where this breaker can be applied in a distribution panel without exceeding its SCCR. Thermal derating is minimal up to 50 °C (full 250 A), then drops to 241 A at 55 °C, 232 A at 60 °C, 222 A at 65 °C, and 213 A at 70 °C. Maximum power dissipation is 50.5 W — account for that heat load in a sealed enclosure. A trip indicator is present, and an undervoltage release (UVR) is integrated as the auxiliary release design. The basic switch supplied is 3VA2225-5HL32-0AA0, and the integrated auxiliary trip is 3VA9608-0BB24.

Dimensions are 181 mm height, 105 mm width, and 86 mm depth — fits standard MCCB panel cutouts and busbar arrangements for 250 A frames.

Frequently asked questions

Where can I buy 3VA2225-5HL32-0CL0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability.

What is the interrupting capacity of 3VA2225-5HL32-0CL0 at different voltages?

187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 5.1 kA at 690 V.

What are the mounting dimensions of 3VA2225-5HL32-0CL0?

Height 181 mm, width 105 mm, depth 86 mm.

MPN
3VA2225-5HL32-0CL0