Skip to main content
Siemens 3VA2225-5HL32-0DF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-5HL32-0DF0 SENTRON MCCB, 250 A, 3-Pole

MPN3VA2225-5HL32-0DF0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2225-5HL32-0DF0, 3-pole, 250 A, line protection, with undervoltage release and auxiliary switch.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-5HL32-0DF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.#BEZUG!
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2225-5HL32-0DF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.50.5 W
3VA2225-5HL32-0DF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2225-5HL32-0DF0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-5HL32-0DF0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2225-5HL32-0DF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-5HL32-0DF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2225-5HL32-0DF0 — 250 A SENTRON MCCB for Line Protection

The Siemens 3VA2225-5HL32-0DF0 is a SENTRON molded case circuit breaker (MCCB) rated for 250 A continuous current at 40 °C, configured as a 3-pole line-protection device with an integrated undervoltage release and a 1 auxiliary switch plus 1 trip alarm switch (HQ design). Its interrupting capacity reaches 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 4.5 kA at 690 V — figures that define the fault-current headroom available for selective coordination downstream. The breaker carries a trip indicator and an undervoltage release as standard, and is designed without communication function or ground-fault monitoring.

The 250 A rating holds from 40 °C through 50 °C ambient; above that it derates linearly to 241 A at 55 °C, 232 A at 60 °C, 222 A at 65 °C, and 213 A at 70 °C. Maximum power loss is 50.5 W, a figure to account for in enclosure thermal calculations when the breaker is fully loaded.

Dimensions are 181 mm height, 105 mm width, and 86 mm depth — a standard 3-pole MCCB footprint that fits SENTRON 3VA2 panel cutouts and busbar systems. The 86 mm depth (3.39 in) is the dimension to check against enclosure gland-plate clearance and door-mounted operator mechanisms.

Frequently asked questions

What is the depth of 3VA2225-5HL32-0DF0?

The depth is 86 mm (3.39 in).

Does 3VA2225-5HL32-0DF0 include an undervoltage release?

Yes, it is equipped with an undervoltage release (UVR) as part of the auxiliary release design.

MPN
3VA2225-5HL32-0DF0