Specifications

3VA2225-5HL32-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2225-5HL32-0HH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W
3VA2225-5HL32-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2225-5HL32-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-5HL32-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2225-5HL32-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-5HL32-0HH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2225-5HL32-0HH0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current at 40 °C, designed for line protection in distribution panels. It carries a short-circuit breaking capacity of 187 kA at 240 V and 121 kA at 415 V, which means it can safely interrupt faults up to those levels without cascading upstream — critical for maintaining selectivity in a multi-level distribution system. The 250 A rating holds flat up to 50 °C, then derates to 241 A at 55 °C and 213 A at 70 °C, so the actual ampacity in a warm enclosure needs a check against the thermal curve.

Auxiliaries and integration

The basic switch assembly is order code 3VA2225-5HL32-0AA0. Panel footprint: 105 mm wide, 181 mm tall, 86 mm deep — standard for the SENTRON 3VA frame size, so it drops into existing DIN-rail or panel-mount cutouts without rework.

Operating temperature range is -25 °C to 70 °C; storage from -40 °C to 80 °C. Maximum power loss is 48 W.

Frequently asked questions

What is the depth of 3VA2225-5HL32-0HH0?

The depth is 86 mm (3.39 in).

What is the width of 3VA2225-5HL32-0HH0?

The width is 105 mm (4.13 in).

MPN
3VA2225-5HL32-0HH0