Siemens 3VA2225-5HL42-0AB0 SENTRON MCCB, 250 A, 187 kA at 24

MPN3VA2225-5HL42-0AB0

Siemens SENTRON molded case circuit breaker, 3VA2225-5HL42-0AB0, 4-pole, 250 A continuous, interrupting 187 kA at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-5HL42-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-5HL42-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA2225-5HL42-0AB0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W
3VA2225-5HL42-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2225-5HL42-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-5HL42-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2225-5HL42-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-5HL42-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

What this MCCB does on the line

The Siemens SENTRON 3VA2225-5HL42-0AB0 is a 4-pole molded case circuit breaker rated for 250 A continuous current at 40 °C, with a maximum interrupting capacity of 187 kA at 240 V. The 250 A frame holds solid up to 70 °C ambient (derated to 213 A at that temp), so it handles a warm panel without tripping early.

Panel fit and footprint

That 86 mm depth means it clears most shallow enclosures without bumping the gland plate. Four-pole construction takes up the full width; if you're swapping from a three-pole unit, plan for an extra 35 mm or so of DIN rail space.

Frequently asked questions

What is the interrupting capacity of this MCCB at 240 V?

The 3VA2225-5HL42-0AB0 is rated to interrupt 187 kA at 240 V, which covers high-fault-current scenarios typical near large transformers.

Will 3VA2225-5HL42-0AB0 drop into a panel that was specified around 3VA2116-5HL32-0AK0 without rewiring?

Both breakers share the same SENTRON 3VA frame dimensions (140 mm wide, 181 mm tall, 86 mm deep), so the mechanical fit is identical. However, the 3VA2225-5HL42-0AB0 is a 250 A, 4-pole unit while the 3VA2116-5HL32-0AK0 is a lower-current 3-pole design — verify busbar and lug sizing before swapping.

Where can I buy 3VA2225-5HL42-0AB0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2225-5HL42-0AB0