Siemens 3VA2225-5HN32-0DL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-5HN32-0DL0 SENTRON MCCB, 250 A, 3-Pole, Line

MPN3VA2225-5HN32-0DL0

Siemens SENTRON 3VA series molded case circuit breaker, 3VA2225-5HN32-0DL0, 250 A, 3-pole, line protection, with undervoltage release and auxiliary switch package.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-5HN32-0DL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2225-5HN32-0DL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.50.5 W

Protection & Trip Unit

3VA2225-5HN32-0DL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2225-5HN32-0DL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-5HN32-0DL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2225-5HN32-0DL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-5HN32-0DL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Ratings and What They Mean for Fit

The 3VA2225-5HN32-0DL0: At 250 A continuous (rated at 40 °C through 50 °C without derating), this MCCB handles the full load current of a 250 A bus or feeder without nuisance tripping. The thermal derating curve is documented: at 55 °C it holds 241 A, at 60 °C it holds 232 A, and at 70 °C it holds 213 A — critical when the breaker lives in a hot enclosure or near other heat sources. The interrupting ratings span from 187 kA at 240 V down to 4.5 kA at 690 V; for a 480 V panel fed by a transformer with 65 kA available fault current, the 121 kA at 440 V rating provides comfortable margin. The 3-pole design with line-protection trip curve means it clears phase faults and overloads on a feeder or main, not motor or generator protection.

Auxiliary Configuration and Panel Integration

This variant ships with an undervoltage release (UVR) and a full auxiliary switch complement: 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch (HQ designation). The UVR ensures the breaker drops out on loss of control voltage — a standard requirement for emergency-stop circuits or undervoltage protection on motor control centers. The auxiliary switches provide status feedback to a PLC or annunciator panel. The base switch supplied is 3VA2225-5HN32-0AA0, meaning the UVR and aux package are factory-integrated, not field-added. Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint for DIN-rail or panel-mount installation.

Frequently asked questions

What are the interrupting ratings for 3VA2225-5HN32-0DL0?

The interrupting capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 4.5 kA at 690 V. For a typical 480 V panel, the 121 kA at 440 V rating covers most high-fault installations.

What auxiliary switches and releases come with this MCCB?

This variant includes an undervoltage release (UVR), 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch (HQ). The UVR drops the breaker on control-voltage loss, and the aux switches provide status feedback.

How do I get pricing and availability for 3VA2225-5HN32-0DL0?

The part is sourced to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time — no figures are carried on this listing.

MPN
3VA2225-5HN32-0DL0