Skip to main content
Siemens 3VA2225-5HN42-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-5HN42-0AD0 SENTRON MCCB, 250 A, 4P, ETU350

MPN3VA2225-5HN42-0AD0

Siemens SENTRON 3VA2225-5HN42-0AD0, molded case circuit breaker, 4-pole, 250 A, ETU350 electronic trip unit, 187 kA at 240 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-5HN42-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2225-5HN42-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2225-5HN42-0AD0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V5.1 kA
Power loss, max.48 W
3VA2225-5HN42-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2225-5HN42-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-5HN42-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2225-5HN42-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-5HN42-0AD0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm

Product details

The 187 kA interrupting rating at 240 V and 121 kA at 415 V place it in the high-fault category for industrial switchboards where available fault current exceeds typical 65 kA or 100 kA MCCB ratings. At 690 V the rating drops to 5.1 kA, so this is not a 690 V main breaker — it lives on the 400–480 V side of the transformer. Current-carrying capacity holds at 250 A from 40 °C through 50 °C (–), then derates to 213 A at 70 °C. In a sealed, uncooled enclosure running at 55 °C ambient, expect 241 A available — close enough to the 250 A nameplate that the breaker can serve a 250 A bus without upsizing, provided the enclosure ventilation keeps internal rise under control.

Sizing and coordination

This 3VA2225-5HN42-0AD0 ships without ground-fault monitoring, so the trip unit is configured for phase overcurrent only. The 3 auxiliary switches HQ provide status feedback — useful for remote tripping indication or PLC-driven load shedding. Maximum power loss is 48 W. In a multi-breaker panel, that heat adds up — account for it in the thermal budget when grouping several 250 A frames in a single enclosure. The 140 mm width is standard for a 4-pole SENTRON 3VA2 frame — it occupies the same footprint as the 3VA2225-5HN42-0BB0 variant, so a panel laid out for the -0BB0 accepts this -0AD0 without drilling new mounting holes or re-routing busbars.

For BOM qualification, the supplied basic switch is listed as 3VA2225-5HN42-0AA0 — that is the internal switching mechanism. When ordering replacement or spare units, the complete order code 3VA2225-5HN42-0AD0 is the procurement line item; the -0AA0 subassembly is not a field-replaceable part stocked separately.

MPN
3VA2225-5HN42-0AD0