Specifications

3VA2225-5HN42-0BL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2225-5HN42-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2225-5HN42-0BL0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V5.1 kA
Power loss, max.50.5 W
3VA2225-5HN42-0BL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2225-5HN42-0BL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-5HN42-0BL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2225-5HN42-0BL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-5HN42-0BL0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm

Product details

The 3VA2225-5HN42-0BL0: The interrupting ratings climb steeply with system voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 5.1 kA at 690 V. That means this breaker can be applied on high-fault panels downstream of large transformers without worrying about cascading failure — the SCCR headroom is substantial through 500 V. Thermal derating is mild up to 50 °C (full 250 A), then drops to 241 A at 55 °C, 232 A at 60 °C, 222 A at 65 °C, and 213 A at 70 °C. In a hot enclosure — say, a packed panel near a furnace line — plan for the 70 °C figure if the ambient inside the cabinet hits that limit.

Auxiliary and release complement

If you are replacing an existing unit, confirm those sub-assembly codes match your panel wiring — the UVR coil voltage and the auxiliary contact arrangement are what the control circuit expects.

Maximum power loss is 50.5 W, which matters for thermal management in a sealed enclosure. If the panel already runs warm, factor that dissipation into the cabinet cooling budget.