Skip to main content
Siemens 3VA2225-5JP32-0BL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-5JP32-0BL0 SENTRON MCCB, 250 A, 3-Pole, 187

MPN3VA2225-5JP32-0BL0

Siemens SENTRON 3VA2225-5JP32-0BL0, molded case circuit breaker, 3-pole, 250 A continuous, 187 kA at 240 V, line protection design with communication function and undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-5JP32-0BL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-5JP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2225-5JP32-0BL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.50.5 W
3VA2225-5JP32-0BL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2225-5JP32-0BL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-5JP32-0BL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2225-5JP32-0BL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-5JP32-0BL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB for high-fault panel feeds

The Siemens SENTRON 3VA2225-5JP32-0BL0 is a 3-pole molded case circuit breaker rated for 250 A continuous current at 40 °C, with a maximum interrupting capacity of 187 kA at 240 V. That interrupting rating drops to 121 kA at 415 V and 440 V, then to 75.6 kA at 500 V, and 4.5 kA at 690 V — so the voltage class of your distribution system directly governs the fault current it can clear. The breaker holds its full 250 A rating up to 50 °C ambient; above that it derates linearly to 200 A at 70 °C, which matters for panels with poor airflow or high internal heat rise.

Designed for line protection with a communication function, an undervoltage release (UVR), and an auxiliary switch configuration of 2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ.

Dimensions: 105 mm wide, 181 mm high, 86 mm deep (–). The 105 mm width is standard for a 3-pole MCCB in the SENTRON 3VA platform — fits existing 3VA panel cutouts and busbar systems without modification.

Frequently asked questions

Does 3VA2225-5JP32-0BL0 include a communication function?

Yes, the breaker has a communication function and includes an undervoltage release (UVR) plus a configurable auxiliary switch block: 2 auxiliary switches, 1 trip alarm switch, and 1 electrical alarm switch HQ (–).

MPN
3VA2225-5JP32-0BL0