Siemens 3VA2225-5JP42-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-5JP42-0AG0 SENTRON MCCB, 250A 4P ETU550, 187

MPN3VA2225-5JP42-0AG0

Siemens SENTRON 3VA2 molded case circuit breaker, 250 A, 4-pole, ETU550 electronic trip unit, 187 kA breaking capacity at 240 V, IP40 front, 86 x 140 x 181 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-5JP42-0AG0 — Identification
ParameterValue
Brand / rangeSENTRON
Basic switch (supplied) ref.#BEZUG!
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2225-5JP42-0AG0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W
3VA2225-5JP42-0AG0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2225-5JP42-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-5JP42-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2225-5JP42-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-5JP42-0AG0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The Siemens 3VA2225-5JP42-0AG0 is a 4-pole SENTRON molded case circuit breaker rated 250 A at 40 °C, carrying a full 250 A up to 50 °C before derating begins — at 55 °C it still holds 238 A, and at 70 °C it delivers 200 A. That thermal curve means this breaker can live in a warm panel without stepping down a frame size. Breaking capacity hits 187 kA at 240 V, 121 kA at 415 V and 440 V, then 75.6 kA at 500 V, and 4.5 kA at 690 V. For a 250 A frame, those numbers give serious headroom on high-fault commercial and industrial services — you can coordinate downstream without worrying about the main letting through. The electronic trip unit is an ETU550, which gives you adjustable N-conductor protection (OFF or 20 % to 100 % of phase setting) plus a communication function for remote monitoring or integration into a power management system. A 1 AUX + 1 trip alarm HP auxiliary contact block is built in.

MPN
3VA2225-5JP42-0AG0