Siemens 3VA2225-5JP42-0DF0 Circuit Breaker, 55kA @ 415V, 250

MPN3VA2225-5JP42-0DF0

Siemens 3VA2 series, IEC frame 250 MCCB, breaking capacity class M, Icu=55kA @ 415V, 4-pole, ETU550 LSI electronic trip unit, In=250A, undervoltage release 208-230V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this 3VA2 MCCB carries

The Siemens 3VA2225-5JP42-0DF0 is a 4-pole IEC frame 250 molded-case circuit breaker with a 55 kA breaking capacity at 415 V (class M), sized for main or feeder protection in distribution panels where fault levels run high enough that a standard 36 kA breaker would not hold coordination. Its ETU550 electronic trip unit provides LSI protection — long-time (Ir adjustable 100–250 A), short-time (Isd 0.6–10× In), and instantaneous (Ii 1.5–10× In) — plus adjustable neutral protection (OFF to 100 %), which gives the site engineer the selectivity curves needed to coordinate downstream branch breakers without nuisance tripping on motor inrush. The breaker ships with a nut keeper kit, an undervoltage release (UVR) rated 208–230 V AC 50/60 Hz, one auxiliary switch (HQ), and one trip alarm switch (HQ) — all factory-fitted, so the panel builder does not need to order accessory kits separately for the UVR and signaling contacts.

Integration notes for the panel builder

Mounts on a standard DIN rail or directly to the panel backplate via the frame's four-bolt pattern. The 4-pole form factor occupies roughly 280 mm of DIN width; account for the UVR coil draw when sizing the control transformer feeding the 208–230 V AC circuit. The auxiliary and alarm switches (both HQ type) provide volt-free changeover contacts for remote status indication — wire the trip alarm into the PLC's safety input chain so a breaker trip is visible at the HMI without a separate monitoring relay.

Frequently asked questions

What is the breaking capacity of this breaker?

The 3VA2225-5JP42-0DF0 carries a 55 kA breaking capacity at 415 V AC (IEC class M), which means it can safely interrupt fault currents up to that level without upstream fuses or a current-limiting reactor.

What protection functions does the ETU550 trip unit provide?

The ETU550 provides LSI protection: long-time pickup adjustable 100–250 A, short-time pickup 0.6–10× In, instantaneous pickup 1.5–10× In, and adjustable neutral protection from OFF to 100 % of the phase setting.

Where can I buy 3VA2225-5JP42-0DF0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.