Siemens 3VA2225-5JQ32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-5JQ32-0AJ0 SENTRON MCCB, 250 A, 3-Pole, 187

MPN3VA2225-5JQ32-0AJ0

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2225-5JQ32-0AJ0, 3-pole, 250 A (at 40 °C), line protection, 187 kA at 240 V, with communication function and trip indicator.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-5JQ32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-5JQ32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2225-5JQ32-0AJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W
3VA2225-5JQ32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2225-5JQ32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-5JQ32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2225-5JQ32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-5JQ32-0AJ0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

It is a 3-pole unit rated 250 A at 40 °C, with a full-scale value of 250 A and an initial setting of 50 A. The breaker carries a maximum breaking capacity of 187 kA at 240 V, 121 kA at 415 V, and 4.5 kA at 690 V — the 690 V figure is the tail-off point that governs its use on 690 V systems where fault current is low.

The headline rating is 250 A continuous at 40 °C, but the breaker is thermally rated across a range: it holds 250 A up to 50 °C, then derates to 238 A at 55 °C, 225 A at 60 °C, 213 A at 65 °C, and 200 A at 70 °C. The interrupting ratings span the common industrial voltages: 187 kA at 240 V, 121 kA at both 415 V and 440 V, 75.6 kA at 500 V, and 4.5 kA at 690 V.

It mounts in a standard distribution panel footprint — the 105 mm width is a 3-pole MCCB form factor that fits Siemens SENTRON busbar systems and panelboards.

Frequently asked questions

What is 3VA2225-5JQ32-0AJ0's listed depth?

The depth is 86 mm (3.39 in).

What is 3VA2225-5JQ32-0AJ0's listed width?

The width is 105 mm (4.13 in).

Will 3VA2225-5JQ32-0AJ0 drop into a panel specified around 3VA2225-5JQ32-0AK0 without rewiring?

The 3VA2225-5JQ32-0AJ0 and 3VA2225-5JQ32-0AK0 share the same SENTRON 3VA2 platform, same dimensions (105 mm wide, 181 mm high, 86 mm deep), and same 3-pole form factor. The -0AJ0 variant includes a communication function and a trip indicator; the -0AK0 may differ in auxiliary switch configuration or electronic trip unit. Physically they occupy the same panel cutout and busbar connection, but verify the auxiliary wiring and trip unit settings against your BOM before swapping — the auxiliary switch count and trip curve may differ.

MPN
3VA2225-5JQ32-0AJ0