Siemens 3VA2225-5JQ32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-5JQ32-0BH0 SENTRON MCCB, 250 A, 3-Pole

MPN3VA2225-5JQ32-0BH0

Siemens SENTRON 3VA2225-5JQ32-0BH0, molded case circuit breaker, 3-pole, 250 A (at 40 °C), line protection, with undervoltage release and communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-5JQ32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-5JQ32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2225-5JQ32-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.50.5 W

Protection & Trip Unit

3VA2225-5JQ32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2225-5JQ32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-5JQ32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2225-5JQ32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-5JQ32-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2225-5JQ32-0BH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying 250 A continuously at 40 °C and derating to 200 A at 70 °C. It breaks up to 187 kA at 240 V, 121 kA at 415/440 V, and holds a 4.5 kA rating at 690 V — so the interrupting capacity scales with your system voltage, not a single headline number.

Ratings and what they mean for fit

The 250 A full-scale rating at 40 °C is the continuous current the breaker carries without tripping in a 40 °C ambient. Above that, the thermal curve pulls back: 238 A at 55 °C, 225 A at 60 °C, 213 A at 65 °C, 200 A at 70 °C. If your panel runs hot — say, 55 °C inside a sealed enclosure — the breaker's effective capacity is 238 A, not 250 A. That derating matters for coordination studies. The adjustable thermal-magnetic trip (initial value 50 A, full-scale 250 A) lets you set the overload threshold within that range, so one breaker frame covers a spread of load sizes. The trip indicator confirms the breaker opened on fault, not manual operation. Breaking capacity: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, 4.5 kA at 690 V. For a 480 V system (common in North America), the relevant figure is the 500 V row at 75.6 kA — that's the SCCR the breaker can interrupt without welding or rupturing. At 690 V the capacity drops sharply to 4.5 kA, so it's not a universal high-voltage breaker; it's sized for distribution up to 500 V. Power loss is 50.5 W maximum at rated current — that heat stays inside the panel, so factor it into your enclosure thermal budget if you're stacking multiple breakers in a confined space.

Auxiliaries and integration

This breaker ships with an undervoltage release (UVR) and two auxiliary switches plus one trip alarm switch (HQ configuration). The UVR trips the breaker when control voltage drops below a threshold — standard for safety circuits where loss of control power must open the main contacts. The auxiliary switches report position (open/closed/tripped) to a PLC or status lamp. Communication function is built in, so it can talk to a higher-level system via the SENTRON communication modules or PROFIBUS/PROFINET gateway for remote monitoring and trip-event logging.

Physical fit and panel considerations

Dimensions: 181 mm high, 105 mm wide, 86 mm deep (7.13 x 4.13 x 3.39 in). That 105 mm width is the standard 3-pole MCCB footprint for this SENTRON frame size — it fits the same mounting cutout and busbar pitch as other 3VA2-series breakers. No need to re-drill the panel if you're swapping between 3VA2 variants of the same frame. Operating temperature range: -25 °C to 70 °C; storage: -40 °C to 80 °C. The storage range is wider because the breaker isn't dissipating heat when stored — that's the handling limit, not the running limit.

Sourcing and lifecycle

This is a current-production part from Siemens, part of the SENTRON 3VA family. It is sourced and quoted to order through independent distribution. For volume purchases or BOM commitments, availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

Frequently asked questions

What auxiliaries are included with 3VA2225-5JQ32-0BH0?

It includes an undervoltage release (UVR), two auxiliary switches, and one trip alarm switch (HQ configuration).