Skip to main content
Siemens 3VA2225-6HL32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6HL32-0AJ0 SENTRON MCCB, 250 A, 3-Pole, 242

MPN3VA2225-6HL32-0AJ0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2225-6HL32-0AJ0, 250 A rated continuous current, 3-pole, breaking capacity 242 kA at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-6HL32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11

Ratings

3VA2225-6HL32-0AJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W

Protection & Trip Unit

3VA2225-6HL32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2225-6HL32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-6HL32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2225-6HL32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-6HL32-0AJ0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB delivers

The Siemens SENTRON 3VA2225-6HL32-0AJ0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current, designed for line protection in industrial distribution panels. Its headline breaking capacity hits 242 kA at 240 V AC, dropping to 187 kA at 415 V and 440 V, then 121 kA at 500 V, and 4.5 kA at 690 V — meaning it handles high-fault utility feeds at lower voltages but derates sharply above 500 V, so verify the available fault current at your system voltage before specifying. Thermal derating is published across the full 40 °C to 70 °C ambient range: the breaker holds its full 250 A rating up to 50 °C, then steps down to 241 A at 55 °C, 232 A at 60 °C, 222 A at 65 °C, and 213 A at 70 °C. That curve lets you size the breaker for a warm enclosure without guessing — the 250 A frame is good for most standard panel environments, but a 65 °C switchroom knocks 28 A off the continuous capacity.

Integration and mounting

The 3VA2225-6HL32-0AJ0 measures 105 mm wide, 181 mm tall, and 86 mm deep — a 3-pole MCCB footprint that fits standard Siemens SENTRON mounting bases and busbar systems. The auxiliary switch configuration includes 2 auxiliary switches plus 1 trip alarm switch (HP type), which covers status feedback and remote trip indication without requiring an add-on module. Maximum power loss is 48 W, which matters for thermal budgeting inside a sealed enclosure — account for that dissipation when sizing ventilation or calculating internal temperature rise.

MPN
3VA2225-6HL32-0AJ0