Skip to main content
Siemens 3VA2225-6HL32-0DB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6HL32-0DB0 SENTRON MCCB, 250 A, 3-Pole, Line

MPN3VA2225-6HL32-0DB0

Siemens SENTRON 3VA2225-6HL32-0DB0, molded case circuit breaker, 250 A, 3-pole, line protection, 242 kA at 240 V, undervoltage release, 2 auxiliary switches HP.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-6HL32-0DB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA22256HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA2225-6HL32-0DB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.50.5 W
3VA2225-6HL32-0DB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2225-6HL32-0DB0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-6HL32-0DB0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2225-6HL32-0DB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-6HL32-0DB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

It carries a maximum breaking capacity of 242 kA at 240 V, stepping down to 187 kA at 415/440 V, 121 kA at 500 V, and 4.5 kA at 690 V — so it handles high fault currents on the low-voltage side while still clearing faults at higher voltages, though the 690 V rating is modest and worth checking against your system's available fault current. No ground-fault monitoring or communication function is integrated — this is a straightforward thermal-magnetic or electronic trip unit for main feeder or large branch protection.

Above that, it derates: 241 A at 55 °C, 232 A at 60 °C, 222 A at 65 °C, and 213 A at 70 °C. Plan your load margin accordingly, especially in a sealed enclosure.

The 3-pole footprint fits alongside other SENTRON breakers in a distribution board.

Frequently asked questions

Where can I buy 3VA2225-6HL32-0DB0 and get a price?

We source and quote this part to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ and we'll respond with a commercial offer.

What are the key ratings for 3VA2225-6HL32-0DB0?

It's a 3-pole MCCB rated 250 A continuous current with a breaking capacity of 242 kA at 240 V, 187 kA at 415/440 V, 121 kA at 500 V, and 4.5 kA at 690 V. It includes an undervoltage release and two auxiliary switches.

MPN
3VA2225-6HL32-0DB0