Skip to main content
Siemens 3VA2225-6HL32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6HL32-0JC0 SENTRON MCCB, 250 A, 3-Pole, Line

MPN3VA2225-6HL32-0JC0

Siemens SENTRON 3VA2 molded case circuit breaker, 250 A, 3-pole, line protection, ETU320 electronic trip, shunt trip (STL), 2 auxiliary switches HQ, 242 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-6HL32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2225-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2225-6HL32-0JC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V6 kA
Power loss, max.48 W

Protection & Trip Unit

3VA2225-6HL32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320

Construction & Connection

3VA2225-6HL32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-6HL32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2225-6HL32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-6HL32-0JC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What it is and what it does

The Siemens 3VA2225-6HL32-0JC0 is a SENTRON molded case circuit breaker (MCCB) for line protection — the main disconnect and fault interrupter in a distribution panel or motor control center. It's rated 250 A continuous at 40 °C, with a 3-pole configuration and an electronic trip unit ETU320 that provides adjustable overload and short-circuit protection curves. The 242 kA breaking capacity at 240 V means it can safely clear a fault up to that level without upstream fuses or breakers needing to coordinate — that's a serious SCCR number for a 250 A frame.

Key ratings and what they mean for fit

The 250 A rating holds across 40 °C to 50 °C (–), then derates linearly to 213 A at 70 °C — so if your panel ambient runs hot, you'll need to account for that. Breaking capacity drops from 242 kA at 240 V to 187 kA at 415 V and 6 kA at 690 V; the 690 V figure is low, so this breaker is best suited for 240–480 V systems where the high interrupt rating matters. The shunt trip (STL) release allows remote tripping via a control signal — common for emergency-stop circuits or undervoltage protection schemes. Two HQ auxiliary switches provide status feedback to a PLC or annunciator panel.

Panel integration and mounting

Dimensions are 105 mm wide, 181 mm high, 86 mm deep — fits standard 3VA2 panel cutouts and busbar systems. The 3-pole frame mounts via screw terminals or plug-in base; no DIN-rail mounting on this class. Plan for 48 W maximum power loss in the enclosure thermal budget.

Frequently asked questions

What is the breaking capacity of 3VA2225-6HL32-0JC0 at 240 V?

242 kA at 240 V, dropping to 187 kA at 415 V and 6 kA at 690 V. The high 240 V rating suits it for heavy fault-current applications like transformer secondaries or large motor starters.

How do I get pricing and availability for 3VA2225-6HL32-0JC0?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; current pricing and lead time are confirmed at quote time.

What auxiliary options are built into 3VA2225-6HL32-0JC0?

It includes a shunt trip (STL) release for remote tripping and two HQ auxiliary switches for status indication. No undervoltage release or communication function is fitted.

MPN
3VA2225-6HL32-0JC0