Skip to main content
Siemens 3VA2225-6HL42-0BF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6HL42-0BF0 Circuit Breaker, 250A, 85kA @ 415

MPN3VA2225-6HL42-0BF0

Siemens 3VA2 IEC frame 250, breaking capacity class H, 4-pole circuit breaker, 85 kA @ 415 V, ETU320 LI trip unit, In = 250 A, with undervoltage release 24 V DC accessory.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 3VA2225-6HL42-0BF0 is a 4-pole IEC frame 250 circuit breaker in breaking capacity class H, rated for 85 kA interrupting capacity at 415 V. It carries an ETU320 LI trip unit with a nominal current In = 250 A, overload protection adjustable Ir = 100 A to 250 A, and short-circuit protection Ii = 1.5 to 10 × In. The N-conductor protection is adjustable (OFF, 50%, 100%). An integrated undervoltage release (24 V DC) is included as an accessory for 3VA1 and 3VA20 frames, plus one auxiliary contact.

What the ratings mean for fit

The 85 kA Icu at 415 V places this breaker in the high-interrupting-capacity class (class H), meaning it can safely clear fault currents up to that level without upstream fuses or cascading — critical for high-fault installations like transformer secondaries or large motor control centers. The ETU320 LI electronic trip unit provides adjustable long-time (overload) and instantaneous (short-circuit) protection curves, letting you dial in Ir between 100 A and 250 A to match cable or busbar ampacity. The adjustable N-conductor protection (OFF, 50%, 100%) is useful for 4-wire systems where neutral current monitoring is required by code or design.

Panel integration notes

This is a 4-pole IEC frame 250 breaker — mounts in a standard switchboard or panel enclosure with busbar or cable connections. The included nut keeper kit simplifies torque-verified lug installation. The undervoltage release (24 V DC) is factory-integrated; verify coil polarity before energizing. The auxiliary contact provides a status signal for PLC or SCADA monitoring. No DIN-rail mounting — this is a bolted-frame breaker for fixed or draw-out chassis.

Frequently asked questions

What is the breaking capacity of 3VA2225-6HL42-0BF0?

The breaking capacity is 85 kA at 415 V (Icu), placing it in breaking capacity class H for high-fault applications.

Where can I buy 3VA2225-6HL42-0BF0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What trip unit does this breaker use?

It uses an ETU320 LI electronic trip unit with adjustable long-time (Ir = 100 A to 250 A) and instantaneous (Ii = 1.5 to 10 × In) protection.

MPN
3VA2225-6HL42-0BF0