The Siemens 3VA2225-6HN32-0AA0 is a SENTRON molded case circuit breaker rated for 250 A continuous current at 40 °C, with the same rating holding through 50 °C before a gradual derating curve begins (241 A at 55 °C, down to 213 A at 70 °C). That 250 A frame makes it a fit for main feeders or large motor branch circuits in commercial and industrial distribution panels. Breaking capacity is 242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4.5 kA at 690 V — so the high interrupting rating at the lower voltages means this breaker can sit ahead of a transformer or at the service entrance where fault currents are stiff. No voltage-trip or undervoltage release is fitted from the factory, so if you need shunt-trip or UVR for emergency-off or generator transfer, that has to be added as an accessory.

Siemens 3VA2225-6HN32-0AA0 SENTRON MCCB, 250 A, 3-Pole, ETU3
MPN3VA2225-6HN32-0AA0
Active
Siemens SENTRON 3VA2225-6HN32-0AA0, molded case circuit breaker, 3-pole, 250 A, ETU350 electronic trip unit, 242 kA at 240 V AC.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Parameter | Value |
|---|---|
| Number of poles | 3 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 250 A |
| Current at 45 °C | 250 A |
| Current at 50 °C | 250 A |
| Current at 55 °C | 241 A |
| Current at 60 °C | 232 A |
| Current at 65 °C | 222 A |
| Current at 70 °C | 213 A |
| Switching capacity class | H |
| Breaking capacity at 240 V | 242 kA |
| Breaking capacity at 415 V | 187 kA |
| Breaking capacity at 440 V | 187 kA |
| Breaking capacity at 500 V | 121 kA |
| Breaking capacity at 690 V | 4.5 kA |
| Power loss, max. | 48 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | ETU350 |
| Overcurrent protection function | LSI |
| Ground-fault monitoring | Without |
| Grounding protection function | No |
| Parameter | Value |
|---|---|
| Main circuit connection type | on both sides nut keeper kit |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | No |
| Voltage trigger | No |
| Trip indicator | No |
| Communication function | No |
| Measurement function | No |
| Motor drive option | Yes |
| Auxiliary CO contacts | 0 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 25 000 |
| Height | 181 mm |
| Width | 105 mm |
| Depth | 86 mm |
| Height (in) | 7.13 in |
| Width (in) | 4.13 in |
| Depth (in) | 3.39 in |
Product details
Frequently asked questions
What trip unit does this breaker use?
The ETU350 electronic trip unit with adjustable long-time, short-time, instantaneous, and ground-fault protection.
MPN
3VA2225-6HN32-0AA0