Siemens 3VA2225-6HN32-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6HN32-0DC0 SENTRON MCCB, 250 A, 3-Pole, 242

MPN3VA2225-6HN32-0DC0

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2225-6HN32-0DC0, 250 A continuous, 3-pole, 242 kA breaking capacity at 240 V AC, line protection design with undervoltage release and 2 auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-6HN32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-6HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2225-6HN32-0DC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.50.5 W

Protection & Trip Unit

3VA2225-6HN32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2225-6HN32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-6HN32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2225-6HN32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-6HN32-0DC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2225-6HN32-0DC0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current at 40 °C, designed for line protection in distribution panels. Its breaking capacity reaches 242 kA at 240 V AC and 187 kA at 415 V, with a derated 4.5 kA at 690 V — the high interrupting ratings make it suited for main feeder duty where fault currents are substantial.

Ratings and what they mean for fit

Continuous current holds at 250 A from 40 °C through 50 °C ambient, then derates to 241 A at 55 °C and 213 A at 70 °C — useful to know if the breaker sits in a warm enclosure or near other heat sources. Breaking capacity varies sharply with system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4.5 kA at 690 V. The 690 V figure is the one that catches people — if your panel runs 690 V line-to-line, this breaker is only good for 4.5 kA fault current, so verify the available fault current at that voltage before specifying. Power loss at rated current is 50.5 W maximum — factor that into enclosure thermal calculations, especially in a multi-breaker lineup. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The storage max is higher because the breaker isn't carrying current — handling, not running, is what that limit governs.

Built-in accessories

This variant ships with an undervoltage release (UVR) and two auxiliary switches (HQ design) factory-installed. The UVR trips the breaker when control voltage drops below a threshold — common for emergency-stop chains or undervoltage protection schemes. The auxiliary switches provide status feedback (open/closed) to a PLC or indication lamp. No ground-fault monitoring or communication function is included on this order code — it is a straight line-protection breaker with the UVR and aux switches as the integrated extras.

Panel fit and dimensions

Dimensions are 181 mm high, 105 mm wide, and 86 mm deep — a standard 3-pole MCCB footprint for DIN-rail or panel-mount installation. The 105 mm width is the same as other 3VA2 3-pole frames in the 250 A class, so swapping within the series usually keeps the same bus bar spacing and mounting hole pattern.

Frequently asked questions

What is the breaking capacity of 3VA2225-6HN32-0DC0 at 415 V?

187 kA at 415 V AC, and the same at 440 V. At 240 V it reaches 242 kA.

Where can I buy 3VA2225-6HN32-0DC0 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the continuous current rating of this MCCB at 60 °C?

232 A at 60 °C ambient. The breaker is rated 250 A from 40 °C through 50 °C, then derates stepwise.