Skip to main content
Siemens 3VA2225-6HN32-0JH0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA2225-6HN32-0JH0 MCCB, 250 A, 3-Pole, 242 kA at 24

MPN3VA2225-6HN32-0JH0

SENTRON 3VA2225-6HN32-0JH0, molded case circuit breaker, 250 A continuous, 3-pole, 242 kA interrupting at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-6HN32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-6HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2225-6HN32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W
3VA2225-6HN32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2225-6HN32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-6HN32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2225-6HN32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-6HN32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The SENTRON 3VA2225-6HN32-0JH0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current, designed for line protection in distribution panels and switchgear. Its interrupting capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4.5 kA at 690 V — figures that govern its ability to clear a fault without upstream damage.

At 40 °C, 45 °C, and 50 °C the breaker holds its full 250 A rating. Derating begins at 55 °C (241 A), dropping to 213 A at 70 °C — a continuous-current curve that matters when the breaker sits in a crowded, warm enclosure. Dimensions are 105 mm wide, 181 mm tall, and 86 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount installations without rework.

Frequently asked questions

What auxiliary switches and releases does this MCCB include?

It includes two auxiliary switches plus one trip alarm switch (HQ) and a shunt trip release (STL).

MPN
3VA2225-6HN32-0JH0