Skip to main content
Siemens 3VA2225-6JP32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6JP32-0AH0 SENTRON MCCB, 250 A, 242 kA

MPN3VA2225-6JP32-0AH0

Siemens SENTRON 3VA2 series, molded case circuit breaker, order code 3VA2225-6JP32-0AH0, 250 A rated current, 242 kA breaking capacity at 240 V, ETU550 electronic trip unit, 3-pole, line protection version.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-6JP32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2225-6JP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2225-6JP32-0AH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V6 kA
Power loss, max.48 W
3VA2225-6JP32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
3VA2225-6JP32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-6JP32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2225-6JP32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-6JP32-0AH0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The headline breaking capacity is 242 kA at 240 V AC, stepping down to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 6 kA at 690 V — that 242 kA figure at 240 V tells you this breaker is sized for high-fault utility or transformer-fed secondary panels where the available fault current is extreme, not for a typical 480 V distribution board where the 187 kA at 415 V is the relevant number. The trip unit is field-configurable, but the base order code ships without auxiliary releases. Thermal derating is published across the operating range: full 250 A up to 50 °C, then 238 A at 55 °C, 225 A at 60 °C, 213 A at 65 °C, and 200 A at 70 °C (–). If your panel ambient inside the enclosure hits 55 °C, you lose 12 A of headroom — plan the load accordingly.

Frequently asked questions

What trip unit does 3VA2225-6JP32-0AH0 use?

It ships with the ETU550 electronic trip unit, configured for line protection — cable and busbar protection, not motor or generator protection.

MPN
3VA2225-6JP32-0AH0