Skip to main content
Siemens 3VA2225-6JP32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6JP32-0HC0 SENTRON MCCB, 250 A, 242 kA at 24

MPN3VA2225-6JP32-0HC0

Siemens SENTRON 3VA2225-6JP32-0HC0, molded case circuit breaker, 3-pole, 250 A, 242 kA at 240 V, ETU550 trip unit, shunt trip, 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-6JP32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2225-6JP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2225-6JP32-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V6 kA
Power loss, max.48 W

Protection & Trip Unit

3VA2225-6JP32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550

Construction & Connection

3VA2225-6JP32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-6JP32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2225-6JP32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-6JP32-0HC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What this MCCB carries and where it fits

The Siemens 3VA2225-6JP32-0HC0 is a SENTRON molded case circuit breaker rated for 250 A continuous current (Iu) with a breaking capacity of 242 kA at 240 V AC — enough to handle high-fault utility feeds or large transformer secondaries without cascading upstream. The 3-pole frame is sized for line protection, not motor or generator duty, so you are buying a feeder breaker, not a starter disconnect. The ETU550 electronic trip unit gives adjustable long-time, short-time, and instantaneous protection curves, plus ground-fault alarm or trip if you add the optional module. The shunt trip (STL) and two HQ auxiliary switches are factory-fitted, so the breaker arrives ready for remote tripping and status feedback — no field-wiring extra blocks. In a cement plant control room or a kiln MCC, the 48 W maximum power loss at full load means the heat stays inside the enclosure; plan your ventilation or derating accordingly. The breaker is rated for ambient operation from -25 °C to 70 °C, so it survives the summer heat next to a preheater without false trips.

Dimensions and panel fit

The 3VA2225-6JP32-0HC0 measures 105 mm wide, 181 mm high, and 86 mm deep — a standard SENTRON 3VA2 frame that drops into most existing MCC buckets or panel cutouts without re-drilling. The 86 mm depth leaves clearance for rear-mounted busbars or wiring troughs in a 400 mm deep enclosure.

Frequently asked questions

How do I get current pricing and availability for 3VA2225-6JP32-0HC0?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time — the part is sourced to order through independent distribution.

What are the key ratings of 3VA2225-6JP32-0HC0?

Rated continuous current Iu is 250 A, breaking capacity reaches 242 kA at 240 V, rated insulation voltage Ui is 800 V, and the maximum power loss is 48 W. The trip unit is an ETU550 with shunt trip and two HQ auxiliary switches.

MPN
3VA2225-6JP32-0HC0