Skip to main content
Siemens 3VA2225-6JP32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6JP32-0HC0 SENTRON MCCB, 250 A, 242 kA at 24

MPN3VA2225-6JP32-0HC0

Siemens SENTRON 3VA2225-6JP32-0HC0, molded case circuit breaker, 3-pole, 250 A, 242 kA at 240 V, ETU550 trip unit, shunt trip, 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-6JP32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2225-6JP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2225-6JP32-0HC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V6 kA
Power loss, max.48 W
3VA2225-6JP32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
3VA2225-6JP32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-6JP32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2225-6JP32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-6JP32-0HC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The ETU550 electronic trip unit gives adjustable long-time, short-time, and instantaneous protection curves, plus ground-fault alarm or trip if you add the optional module. The shunt trip (STL) and two HQ auxiliary switches are factory-fitted, so the breaker arrives ready for remote tripping and status feedback — no field-wiring extra blocks.

The 3VA2225-6JP32-0HC0 measures 105 mm wide, 181 mm high, and 86 mm deep — a standard SENTRON 3VA2 frame that drops into most existing MCC buckets or panel cutouts without re-drilling. The 86 mm depth leaves clearance for rear-mounted busbars or wiring troughs in a 400 mm deep enclosure.

Frequently asked questions

How do I get current pricing and availability for 3VA2225-6JP32-0HC0?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time — the part is sourced to order through independent distribution.

What are the key ratings of 3VA2225-6JP32-0HC0?

Rated continuous current Iu is 250 A, breaking capacity reaches 242 kA at 240 V, rated insulation voltage Ui is 800 V, and the maximum power loss is 48 W. The trip unit is an ETU550 with shunt trip and two HQ auxiliary switches.

MPN
3VA2225-6JP32-0HC0