Siemens 3VA2225-6JP42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6JP42-0AA0 SENTRON MCCB, 4-pole, 250 A, ETU5

MPN3VA2225-6JP42-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 4-pole, 250 A, ETU550 electronic trip unit, line protection design, IP40 front, 140 × 181 × 86 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-6JP42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2225-6JP42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W

Protection & Trip Unit

3VA2225-6JP42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2225-6JP42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-6JP42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2225-6JP42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-6JP42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

Siemens 3VA2225-6JP42-0AA0 SENTRON 4-Pole MCCB, 250 A, ETU550

The Siemens 3VA2225-6JP42-0AA0 is a SENTRON-series molded case circuit breaker (MCCB) designed for line protection in 3-phase + neutral distribution. It carries 250 A continuous at 40 °C, with the ETU550 electronic trip unit providing adjustable overload and short-circuit protection curves. Rated for 4-pole operation, it handles neutral protection in TN or TT systems without a separate N breaker. The 250 A rating holds flat from 40 °C to 50 °C, then derates linearly to 200 A at 70 °C — critical overhead for panels packed near heat sources. Short-circuit interrupting capacity reaches 242 kA at 240 V, 187 kA at 415/440 V, 121 kA at 500 V, and 4.5 kA at 690 V. The 690 V figure looks low because the arc extinction physics shift at that voltage — verify the available fault current at your service voltage before specifying.

Integration & Mounting

Footprint is 140 mm wide × 181 mm tall × 86 mm deep — fits standard Siemens 3VA2 panel cutouts and busbar systems. IP40 on the front face means it's protected against tools and wires >1 mm, but not against water ingress; mount inside a rated enclosure for wet or washdown environments. Power loss at full rated current is 48 W maximum. In a sealed enclosure with multiple breakers ganged, account for that dissipation in the thermal budget — 250 A continuous through the poles generates measurable heat. Communication function is built in — the ETU550 supports optional communication modules for remote monitoring and trip-event logging. No undervoltage release or ground-fault monitoring is fitted on this variant; those are separate accessory options.

Environmental & Compliance

Operating temperature range is -25 °C to +70 °C; storage from -40 °C to +80 °C. Insulation voltage rated at 800 V. The 3VA2 series carries UL, CSA, and IEC certifications typical for SENTRON — compliance documentation including RoHS and REACH declarations is available through Siemens support channels.

Frequently asked questions

What is the interrupting capacity of 3VA2225-6JP42-0AA0 at different voltages?

242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4.5 kA at 690 V. The sharp drop at 690 V is normal for MCCBs — arc extinction in air is less efficient at higher voltages.

Will 3VA2225-6JP42-0AA0 drop into a panel specified around 5SQ2670-2YA63?

Not directly. The 5SQ2670 series is a different Siemens product family with different mounting footprint and busbar interface. The 3VA2 uses a 140 mm wide body versus the 5SQ's narrower frame. Panel cutouts and busbar drilling would need rework.

How do I get current pricing and availability for 3VA2225-6JP42-0AA0?

Submit an RFQ through this listing. The part is sourced to order via independent distribution channels; availability and current pricing are confirmed at quote time.

MPN
3VA2225-6JP42-0AA0