Skip to main content
Siemens 3VA2225-6JQ32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6JQ32-0DA0 SENTRON MCCB, 250 A, 3-Pole, UVR

MPN3VA2225-6JQ32-0DA0

Siemens SENTRON 3VA2225-6JQ32-0DA0, molded case circuit breaker, line protection, 3-pole, 250 A adjustable from 50 A, 242 kA interrupting at 240 V, undervoltage release, communication function.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-6JQ32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-6JQ32-0AA0
3VA2225-6JQ32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.50.5 W
3VA2225-6JQ32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2225-6JQ32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-6JQ32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2225-6JQ32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-6JQ32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2225-6JQ32-0DA0 is a 3-pole molded case circuit breaker designed for line protection, rated 250 A continuous at 40 °C with an adjustable trip range from 50 A up to 250 A full-scale. Interrupting capacity hits 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4.5 kA at 690 V — so the 240 V figure is the headline for high-fault panels, but the drop at 690 V means you need coordination study if you're running that voltage. Maximum power loss is 50.5 W — factor that into enclosure ventilation if you're stacking several in a panel.

Thermal derating and physical fit

Continuous rating holds at 250 A from 40 °C through 50 °C, then derates to 238 A at 55 °C, 225 A at 60 °C, 213 A at 65 °C, and 200 A at 70 °C — so in a warm enclosure you lose about 20% by the top of the operating range.

Frequently asked questions

Does this breaker include an undervoltage release?

Yes, an undervoltage release (UVR) is fitted as the auxiliary release.

MPN
3VA2225-6JQ32-0DA0