Siemens 3VA2225-6KP32-0BH0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA2225-6KP32-0BH0 MCCB, 250 A, 242 kA at 240 V

MPN3VA2225-6KP32-0BH0

Siemens SENTRON 3VA2225-6KP32-0BH0, molded case circuit breaker (MCCB), 3-pole, 250 A continuous, 242 kA breaking at 240 V AC, line protection design with undervoltage release and communication function.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-6KP32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-6KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2225-6KP32-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.50.5 W

Protection & Trip Unit

3VA2225-6KP32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2225-6KP32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-6KP32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2225-6KP32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-6KP32-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what it does

The Siemens SENTRON 3VA2225-6KP32-0BH0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current at 40 °C, with a maximum breaking capacity of 242 kA at 240 V AC. That 242 kA rating means it can safely interrupt a fault current up to that level — critical for high-fault installations like transformer secondaries or large motor control centers where upstream coordination demands a high-interrupt device. The breaker is designed for line protection, meaning it's the primary overcurrent protection for a feeder or main, not a downstream branch device. The 250 A continuous rating holds flat from 40 °C through 50 °C, then derates linearly to 200 A at 70 °C. If your panel ambient runs above 50 °C, plan on the lower figure — the breaker doesn't lose capacity until 55 °C, but above that the thermal curve is real. For a 250 A feeder in a 60 °C enclosure, you're effectively working with a 225 A device.

Breaking capacity across voltages

Breaking capacity drops with system voltage: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 4.5 kA at 690 V. The 4.5 kA at 690 V is the weak point — if your 690 V fault current exceeds that, this breaker isn't the right choice. For typical 480 V北美 panels, 121 kA is ample for most transformer ratings up to 2500 kVA.

Built-in auxiliaries and releases

This variant ships with an undervoltage release (UVR) and two auxiliary switches plus one trip alarm switch (HQ configuration). The UVR means the breaker trips when control voltage drops below a threshold — standard for safety circuits where loss of control power must open the main. The communication function suggests it's ready for integration into a higher-level monitoring system, though the protocol isn't specified in the base listing. A trip indicator gives local visual status.

Physical fit and environment

Dimensions: 181 mm high, 105 mm wide, 86 mm deep. That 105 mm width is standard for a 3-pole 250 A frame — it'll fit a typical MCC bucket or panel mount without surprises. Operating temperature range is -25 °C to 70 °C; storage from -40 °C to 80 °C. The 50.5 W maximum power loss matters for thermal management in sealed enclosures — at full load, that's heat that needs to be vented or dissipated.

Frequently asked questions

What is the breaking capacity of 3VA2225-6KP32-0BH0 at 415 V?

187 kA at 415 V AC, same as at 440 V.

What auxiliaries come with this breaker?

It includes an undervoltage release (UVR), two auxiliary switches, and one trip alarm switch (HQ configuration).

Where can I buy 3VA2225-6KP32-0BH0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2225-6KP32-0BH0