Siemens 3VA2225-6KP32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2225-6KP32-0JC0 MCCB, 250 A, 3-Pole, Line

MPN3VA2225-6KP32-0JC0

Siemens SENTRON 3VA2225-6KP32-0JC0, molded case circuit breaker, 3-pole, 250 A, line protection, 242 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-6KP32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-6KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2225-6KP32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W

Protection & Trip Unit

3VA2225-6KP32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2225-6KP32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-6KP32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2225-6KP32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-6KP32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Molded Case Circuit Breaker for Line Protection

The Siemens SENTRON 3VA2225-6KP32-0JC0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current at 40 °C, designed for line protection in industrial power distribution panels. Its breaking capacity reaches 242 kA at 240 V and 187 kA at 415 V, meaning it can safely interrupt high fault currents without cascading upstream — critical for maintaining selectivity in a distribution board. The unit includes a shunt trip (STL) release and two auxiliary switches (HQ), enabling remote tripping and status feedback for integration into a safety circuit or power management system.

Thermal Derating and Ambient Performance

The breaker holds its full 250 A rating from 40 °C through 50 °C, then derates linearly to 200 A at 70 °C — a profile that suits enclosed switchgear or high-ambient machine rooms without oversizing. Maximum power loss is 48 W, which should be factored into the enclosure thermal budget, especially when multiple breakers are ganged.

Communication and Auxiliary Functions

This variant includes a communication function, allowing integration with higher-level control or monitoring systems — useful for remote load management or energy monitoring in a facility. The supplied basic switch is order code 3VA2225-6KP32-0AA0; the auxiliary switch block provides two HQ-rated contacts for status indication or interlocking.

Frequently asked questions

Does 3VA2225-6KP32-0JC0 include a shunt trip or auxiliary switches?

Yes, it includes a shunt trip (STL) release and two auxiliary switches (HQ) for remote tripping and status feedback.

MPN