Skip to main content
Siemens 3VA2225-7HN32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-7HN32-0AB0 SENTRON MCCB, 250 A, 3-Pole, 330

MPN3VA2225-7HN32-0AB0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2225-7HN32-0AB0, 250 A rated continuous current, 3-pole, interrupting capacity 330 kA at 240 V AC, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-7HN32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-7HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA2225-7HN32-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W
3VA2225-7HN32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2225-7HN32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-7HN32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2225-7HN32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-7HN32-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Its interrupting capacity is 330 kA at 240 V AC, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 4.5 kA at 690 V — meaning it can safely clear fault currents up to those levels depending on the system voltage, which is critical for maintaining selectivity and protecting downstream equipment in high-fault installations. Rated continuous current holds at 250 A from 40 °C up to 50 °C ambient, then derates to 241 A at 55 °C, 232 A at 60 °C, 222 A at 65 °C, and 213 A at 70 °C — useful when the breaker is installed in a warm enclosure or alongside other heat-generating devices.

Frequently asked questions

Will the 3VA2225-7HN32-0AB0 drop into a panel specified around the 3VA2225-5HN42-0BB0?

Both are 3-pole SENTRON 3VA2 breakers in the same frame size, so the physical footprint (105 mm wide, 181 mm high, 86 mm deep) is identical — no rewiring or panel modification needed for fit.

MPN
3VA2225-7HN32-0AB0