Specifications

3VA2225-7KP32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2225-7KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2225-7KP32-0AD0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V6.3 kA
Power loss, max.48 W
3VA2225-7KP32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
3VA2225-7KP32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-7KP32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts3
3VA2225-7KP32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-7KP32-0AD0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens SENTRON 3VA2225-7KP32-0AD0 is a 3-pole molded case circuit breaker rated for 250 A continuous current at 40 °C, with a breaking capacity of 330 kA at 240 V and 242 kA at 415 V — enough to handle high-fault utility feeds or transformer secondaries without cascading upstream. Three auxiliary switches (HQ type) are built in, so you get status feedback without adding external contact blocks.

This MCCB's interrupting rating drops as system voltage rises: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 6.3 kA at 690 V. At 690 V the 6.3 kA figure is modest — not a high-fault 690 V breaker — so if your panel runs 690 V with available fault current above that, you need a different frame.

Frequently asked questions

How do I get current pricing and availability for 3VA2225-7KP32-0AD0?

Submit an RFQ through this listing. The part is sourced to order; pricing and stock are confirmed at quote time.

What is the breaking capacity of this MCCB at 415 V?

242 kA at 415 V, which covers most industrial high-fault applications at that voltage.

What trip unit does this breaker use?

The ETU850 electronic trip unit, offering adjustable protection curves and communication capability.

Will 3VA2225-7KP32-0AD0 drop into a panel that was specified around 5SQ2370-2YA05 without rewiring?

The 5SQ2370-2YA05 is a different manufacturer's MCCB; footprint and terminal layout are not guaranteed to match. Verify mounting dimensions and lug spacing before substitution.

MPN
3VA2225-7KP32-0AD0