Siemens 3VA2225-7KP32-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-7KP32-0AG0 SENTRON MCCB, 250 A, 3-pole

MPN3VA2225-7KP32-0AG0

Siemens SENTRON 3VA2225-7KP32-0AG0, molded case circuit breaker, 3-pole, 250 A, 330 kA at 240 V, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-7KP32-0AG0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-7KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2225-7KP32-0AG0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W
3VA2225-7KP32-0AG0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2225-7KP32-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-7KP32-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts2
3VA2225-7KP32-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-7KP32-0AG0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2225-7KP32-0AG0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current and a massive 330 kA breaking capacity at 240 V AC. That interrupting rating means it handles high-fault-current scenarios typical in large distribution panels or industrial mains — it clears a short-circuit fault up to 330 kA without failing, protecting downstream equipment. The 250 A frame is thermally rated at 40 °C ambient, and the breaker includes a communication function for integration into a monitored power system.

Breaking capacity and derating

Breaking capacity drops with system voltage: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 4.5 kA at 690 V. The 690 V figure is low — this breaker is not intended for 690 V mains protection. Continuous current derates above 55 °C: 238 A at 55 °C, 225 A at 60 °C, 213 A at 65 °C, 200 A at 70 °C.

Auxiliary switch and trip alarm

The breaker ships with one auxiliary switch and one trip alarm switch (HP design) factory-installed. That gives you a remote status contact for open/closed and a separate contact that signals when the breaker trips on fault.

Dimensions: 181 mm height, 105 mm width, 86 mm depth. Maximum power loss is 48 W at rated current, so account for that heat in the enclosure thermal calculation.

Frequently asked questions

What is 3VA2225-7KP32-0AG0's listed depth?

The depth is 86 mm (3.39 in).

What is 3VA2225-7KP32-0AG0's listed width?

The width is 105 mm (4.13 in).

MPN
3VA2225-7KP32-0AG0