Skip to main content
Siemens 3VA2225-7KQ32-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-7KQ32-0BA0 Circuit Breaker, 250A, 110kA @ 41

MPN3VA2225-7KQ32-0BA0

Siemens 3VA2 series, IEC frame 250, breaking capacity class C, 3-pole, line protection ETU860 LSIG, In=250A, Icu=110kA @ 415V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this breaker is and what it does

The Siemens 3VA2225-7KQ32-0BA0 is a 3-pole IEC frame 250 molded case circuit breaker in the 3VA2 series, carrying a breaking capacity class C rating of Icu=110kA at 415V. That 110kA interrupting rating means it can safely clear a fault up to that level without blowing apart or welding its contacts — critical for high-fault installations like transformer secondaries or large motor control centers where available fault current runs high. The ETU860 electronic trip unit gives you LSIG protection (long-time, short-time, instantaneous, and ground-fault) with adjustable overload protection Ir from 100A to 250A, short-time pickup Isd from 0.6 to 10x In, and instantaneous pickup Ii from 1.5 to 10x In. Ground-fault protection is adjustable Ig from 0.2 to 1x In with time delay tg from 0.05 to 0.8 seconds, and it can be switched off. N-conductor protection is available optionally with an external current transformer, up to 160% of the rated ground-fault setting.

What the key ratings mean for the panel

The 250A frame and adjustable Ir (100A to 250A) let you dial in the exact overload protection for the downstream load without swapping breaker bodies — useful when the same panel build handles multiple motor sizes. The LSIG trip curve with its adjustable time delays gives selectivity coordination with downstream breakers: you can set short-time delay so a feeder fault clears the branch breaker before this main trips. The undervoltage release (24 V DC accessory included per the description) is a standard safety feature: if control voltage drops, the breaker opens, preventing automatic restart after a power loss. This breaker mounts in the standard 3VA panel footprint; the nut keeper kit secures it against vibration in mobile or industrial environments.

Deployment context

This class of breaker is used in main distribution panels, feeder circuits, and large motor branch circuits within industrial and commercial power systems. The 110kA SCCR at 415V makes it suitable for installations with high available fault current — think transformer-fed switchboards or heavy manufacturing plants. The adjustable ground-fault protection (up to 160% with external CT) suits it for systems where ground-fault coordination or arc-flash mitigation is required.

Frequently asked questions

Where can I buy 3VA2225-7KQ32-0BA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2225-7KQ32-0BA0?

It is rated Icu=110kA at 415V, breaking capacity class C per the IEC frame 250 standard.

What trip unit does this breaker use?

It uses the ETU860 electronic trip unit with LSIG protection: adjustable long-time, short-time, instantaneous, and ground-fault settings.

MPN
3VA2225-7KQ32-0BA0