Skip to main content
Siemens 3VA2225-8HL32-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-8HL32-0BA0 SENTRON MCCB, 250 A, 440 kA

MPN3VA2225-8HL32-0BA0

Siemens SENTRON molded case circuit breaker, 3VA2225-8HL32-0BA0, 3-pole, 250 A rated continuous current, ETU320 electronic trip unit, undervoltage release, 440 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-8HL32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2225-8HL32-0AA0
3VA2225-8HL32-0BA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V242 kA
Breaking capacity at 690 V50.4 kA
Power loss, max.50.5 W
3VA2225-8HL32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2225-8HL32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-8HL32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2225-8HL32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-8HL32-0BA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens SENTRON 3VA2225-8HL32-0BA0 is a 3-pole molded case circuit breaker rated for 250 A continuous current at 40 °C to 50 °C, with the ETU320 electronic trip unit handling the overcurrent protection curve. Breaking capacity lands at 440 kA at 240 V, 330 kA at 415/440 V, 242 kA at 500 V, and 50.4 kA at 690 V — numbers that tell you this breaker is built for high-fault utility infeed or large motor control center main service, not branch protection.

Trip unit and release setup

The ETU320 electronic trip unit provides LI (long-time and instantaneous) protection — no ground-fault or voltage-trip function on this variant. An undervoltage release (UVR) is integrated as standard, part number 3VA9608-0BB11 for the release coil itself. No auxiliary contacts, no communication module, no phase-failure detection on this build — it's a clean line-protection breaker for applications where those extras aren't wired into the control scheme.

Thermal derating and endurance

Production status and sourcing posture

This part carries a current production lifecycle stage.

Frequently asked questions

What compliance documentation does this brand provide for 3VA2225-8HL32-0BA0?

Siemens SENTRON MCCBs carry UL, CSA, and IEC certifications standard for the series. RoHS and REACH declarations are available through Siemens documentation channels for this product family.

MPN
3VA2225-8HL32-0BA0