Skip to main content
Siemens 3VA2225-8HL32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-8HL32-0DA0 SENTRON MCCB, 250 A, 3-Pole, UVR

MPN3VA2225-8HL32-0DA0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2225-8HL32-0DA0, 250 A, 3-pole, line protection, undervoltage release, 440 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-8HL32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-8HL32-0AA0

Ratings

3VA2225-8HL32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.50.5 W

Protection & Trip Unit

3VA2225-8HL32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2225-8HL32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-8HL32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2225-8HL32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-8HL32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries

The Siemens 3VA2225-8HL32-0DA0 is a SENTRON 3VA2 molded case circuit breaker rated for 250 A continuous current (at 40 °C through 50 °C) and designed for line protection. It is a 3-pole unit with an integrated undervoltage release (UVR) — the auxiliary release type is specified as undervoltage release. The supplied basic switch is order code 3VA2225-8HL32-0AA0.

Breaking capacity — what it means for fault duty

Breaking capacity is voltage-dependent and ranges from 440 kA at 240 V down to 52.5 kA at 690 V. At 415 V and 440 V it holds 330 kA; at 500 V it drops to 220 kA. This tells you the maximum fault current the breaker can safely interrupt at each voltage level — critical for SCCR coordination studies. If your available fault current at the panel bus exceeds these numbers at the operating voltage, you need a higher-rated upstream device or a current-limiting feeder.

Thermal derating and ambient limits

The 250 A continuous rating holds from 40 °C to 50 °C ambient. Above that it derates linearly: 241 A at 55 °C, 232 A at 60 °C, 222 A at 65 °C, and 213 A at 70 °C. Operating ambient range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. Maximum power loss is 50.5 W — factor that into enclosure thermal calculations if the panel is tightly packed.

Physical fit and panel integration

Dimensions are 105 mm wide, 181 mm high, 86 mm deep. This is a standard 3-pole MCCB footprint for DIN-rail or panel-mount installation. No communication function, no ground-fault monitoring, no auxiliary switch — the only integrated release is the undervoltage release. Trip indicator is not fitted; voltage trigger is absent.

Frequently asked questions

What is the breaking capacity of 3VA2225-8HL32-0DA0 at 415 V?

At 415 V the breaking capacity is 330 kA. At 240 V it is 440 kA; at 690 V it drops to 52.5 kA.

Does 3VA2225-8HL32-0DA0 include an undervoltage release?

Yes, it is fitted with an undervoltage release (UVR) as the auxiliary release type. The design of the auxiliary release is specified as undervoltage release.

Where can I buy 3VA2225-8HL32-0DA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN