Siemens 3VA2225-8HL32-0JL0 SENTRON MCCB, 250 A, 3-Pole

MPN3VA2225-8HL32-0JL0

Siemens SENTRON 3VA2225-8HL32-0JL0, molded case circuit breaker, 3-pole, 250 A continuous, 440 kA breaking capacity at 240 V AC, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-8HL32-0JL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-8HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2225-8HL32-0JL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.48 W

Protection & Trip Unit

3VA2225-8HL32-0JL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2225-8HL32-0JL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-8HL32-0JL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2225-8HL32-0JL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-8HL32-0JL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries and where it fits

The Siemens 3VA2225-8HL32-0JL0 is a SENTRON molded case circuit breaker (MCCB) rated for 250 A continuous current at 40 °C, with a 3-pole configuration designed for line protection. Its breaking capacity reaches 440 kA at 240 V AC and 330 kA at 415 V AC, tapering to 52.5 kA at 690 V AC — a curve that tells you this breaker is built for high-fault industrial distribution, not light commercial panels. The thermal derating is mild: it holds 250 A up to 50 °C, then drops to 241 A at 55 °C and 213 A at 70 °C, so you can size it for a warm enclosure without oversizing the frame.

Auxiliary and release configuration

This variant ships with a shunt trip release (STL) and a full auxiliary switch block: two auxiliary switches plus one trip alarm switch and one electrical alarm switch (HQ designation). The basic switch core is order code 3VA2225-8HL32-0AA0. No undervoltage release, no ground-fault monitoring, no communication module — it's a straight line-protection breaker with remote trip capability via the shunt release.

Physical fit and panel integration

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that mounts on a DIN rail or direct-panel bolted bus. The 86 mm depth is the overall body, not counting handle throw; verify front clearance for the operating mechanism in a shallow enclosure.

Frequently asked questions

Who supplies 3VA2225-8HL32-0JL0 and how is it quoted for volume purchases?

This part is sourced through independent industrial-automation distribution. Volume pricing and lead time are confirmed at quote time against an RFQ — no public price list applies to this channel.

What is 3VA2225-8HL32-0JL0's listed depth on this component line?

The overall body depth is 86 mm (3.39 inches), with a width of 105 mm and height of 181 mm.

What compliance documentation does this brand provide for 3VA2225-8HL32-0JL0?

As a SENTRON MCCB from Siemens, this part typically carries UL, CSA, and IEC certifications appropriate for its breaking capacity ratings. Specific RoHS and REACH declarations are available from the manufacturer's documentation portal using the order code.

Will 3VA2225-8HL32-0JL0 drop into a panel specified around 3VA2163-8HM32-0AA0 without rewiring?

The 3VA2225-8HL32-0JL0 is a different frame size — 250 A continuous versus the 3VA2163's lower rating — so it will not physically interchange without buswork changes. The 3VA2163-8HM32-0AA0 is a smaller-frame MCCB; this 3VA2225 variant requires the larger 3VA2 frame footprint and terminal spacing.

MPN