Siemens 3VA2225-8HL32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-8HL32-0KL0 SENTRON MCCB, 250 A, 3-Pole, 86 m

MPN3VA2225-8HL32-0KL0

Siemens SENTRON 3VA series, molded case circuit breaker, 3VA2225-8HL32-0KL0, 250 A, 3-pole, line protection, 86 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-8HL32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-8HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2225-8HL32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.48 W

Protection & Trip Unit

3VA2225-8HL32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2225-8HL32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-8HL32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2225-8HL32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-8HL32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

SENTRON 3VA2225-8HL32-0KL0 — 250 A MCCB for Line Protection

The Siemens SENTRON 3VA2225-8HL32-0KL0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current, designed specifically for line protection — meaning it's the primary overcurrent device guarding a feeder or main distribution bus, not a motor-protective or ground-fault version. It carries a breaking capacity of 440 kA at 240 V and 330 kA at 415 V, which puts it in the high-interrupting class for industrial switchgear where fault currents can reach extreme levels. The thermal derating curve is published: it holds the full 250 A up to 50 °C ambient, then drops to 241 A at 55 °C and 213 A at 70 °C — so if you're mounting this in a hot enclosure, plan for the reduced ampacity above 50 °C.

Breaking Capacity and Selectivity Headroom

At 690 V the breaker still interrupts 52.5 kA, so it can serve as the main breaker in a 690 V distribution panel feeding step-down transformers or VFD groups. The 2 500 A maximum setting range (with a 375 A minimum) on the electronic trip unit gives wide selectivity coordination with downstream feeders — you can dial the long-time pickup well above the 250 A frame rating to ride through motor starting inrush without nuisance tripping.

Auxiliary and Release Configuration

This variant ships with a shunt trip release (STL) for remote tripping and a full auxiliary switch complement: 2 auxiliary switches + 1 trip alarm switch + 1 electrical alarm switch HQ. That covers remote status indication and emergency shutdown integration without adding external relays. No undervoltage release, no ground-fault monitoring, no communication module — it's a straightforward line-protection MCCB with hardwired signals.

Physical Fit and Panel Integration

Dimensions are 105 mm wide × 181 mm high × 86 mm deep. That 86 mm depth is the overall body — it fits standard MCCB mounting footprints in 600 mm deep enclosures with room for rear-access wiring. The 3-pole format matches common busbar layouts. Maximum power loss is 48 W at rated current, so factor that into enclosure ventilation if you're grouping several breakers in a sealed cabinet.

Environmental and Compliance

Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The trip indicator and voltage trigger are present, giving visual and electrical status for troubleshooting. As a SENTRON series MCCB, it carries Siemens' standard compliance documentation (IEC 60947-2, UL 489) — the specific certs for this order code should be verified against the factory certificate for your jurisdiction.

Frequently asked questions

How do I get current pricing and availability for 3VA2225-8HL32-0KL0?

Pricing and availability are confirmed at the time of quote against an RFQ through independent distribution. Submit a request for current market pricing and lead time.

What is 3VA2225-8HL32-0KL0's listed depth?

The depth is 86 mm (3.39 in). This is the overall body depth, suitable for standard 600 mm deep enclosures with rear-access wiring clearance.

What auxiliary switches and releases does this breaker include?

It includes 2 auxiliary switches, 1 trip alarm switch, 1 electrical alarm switch HQ, and a shunt trip release (STL). It does not include an undervoltage release or ground-fault monitoring.

MPN
3VA2225-8HL32-0KL0