Skip to main content
Siemens 3VA2225-8KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-8KQ42-0AA0 SENTRON MCCB, 250A, 4P, 440kA

MPN3VA2225-8KQ42-0AA0
Active

Siemens SENTRON 3VA2 series molded case circuit breaker, 3VA2225-8KQ42-0AA0, 250 A rated continuous current, 4-pole, line protection with ground-fault monitoring, interrupting capacity 440 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2225-8KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2225-8KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.48 W
3VA2225-8KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes
3VA2225-8KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-8KQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2225-8KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-8KQ42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

SENTRON 3VA2 — 250 A, 4-Pole MCCB for Line Protection

It carries a full-scale value of 250 A with an initial setting of 50 A, covering feeder and main distribution applications in LV switchgear. Interrupting capacity is the headline here: 440 kA at 240 V AC, 330 kA at 415/440 V, 220 kA at 500 V, and 52.5 kA at 690 V. Thermal derating is published across the operating range: full 250 A up to 50 °C, then 238 A at 55 °C, 225 A at 60 °C, 213 A at 65 °C, and 200 A at 70 °C. Ground-fault monitoring uses summation current formation on L + N conductors, so it detects residual fault current without a separate GFCI module. Communication function is onboard, enabling integration with higher-level monitoring systems for selective coordination and event logging.

Maximum power loss is 48 W under rated load, which factors into enclosure thermal calculations — not a selection parameter but relevant for panel ventilation planning in sealed cabinets. Dimensions: 181 mm height × 140 mm width × 86 mm depth (7.13 × 5.51 × 3.39 in).

Integration & Environment

The 70 °C operating ceiling matches the derated current of 200 A at that limit — the breaker runs but needs the derating applied. No undervoltage release or voltage trip is fitted on this variant — the trip indicator is also absent. These are optional accessories in the 3VA2 family; if UVR or trip-flag indication is required for the application, the -8KQ42-0AA0 suffix doesn't include them.

Frequently asked questions

What are the physical dimensions of 3VA2225-8KQ42-0AA0?

181 mm height × 140 mm width × 86 mm depth (7.13 × 5.51 × 3.39 inches).

Does 3VA2225-8KQ42-0AA0 have ground-fault protection?

Yes, it includes summation current formation ground-fault monitoring on L + N conductors, detecting residual fault current without a separate module.

Will 3VA2225-8KQ42-0AA0 drop into a panel specified around 5SQ2670-2YA63?

Panel cutout and bus-bar spacing are compatible between the 3VA2 and the earlier 5SQ series for most retrofits. The 3VA2 adds onboard communication and summation ground-fault monitoring that the older variant lacks.

MPN
3VA2225-8KQ42-0AA0