Skip to main content
Siemens 3VA2325-5HK32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-5HK32-0AA0 SENTRON MCCB, 250 A, 3-Pole, ETU3

MPN3VA2325-5HK32-0AA0
Active

Siemens SENTRON 3VA2325-5HK32-0AA0, 3-pole molded case circuit breaker, 250 A rated current, ETU340 electronic trip unit, line protection design, breaking capacity 187 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2325-5HK32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2325-5HK32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.37.5 W
3VA2325-5HK32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340
Overcurrent protection functionELISA LI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2325-5HK32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2325-5HK32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2325-5HK32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2325-5HK32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

250 A MCCB with ETU340 — selectivity and SCCR planning

The Siemens SENTRON 3VA2325-5HK32-0AA0 is a 3-pole molded case circuit breaker rated 250 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to that ceiling. Breaking capacity runs 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V; the 690 V figure is the one to watch if you are feeding a 690 V drive line — that is a low-fault scenario where the upstream transformer impedance does the heavy lifting.

Dimensions are 248 mm high, 138 mm wide, 110 mm deep — a standard 3-pole MCCB footprint for SENTRON 3VA2 frames.

Frequently asked questions

How do I get pricing and availability for 3VA2325-5HK32-0AA0?

Submit an RFQ through this listing. Current pricing and stock levels are confirmed at quote time through independent distribution channels.

What is the breaking capacity of 3VA2325-5HK32-0AA0 at 415 V?

121 kA at 415 V AC, matching the 121 kA rating at 440 V. At 240 V it is 187 kA, at 500 V it is 75.6 kA, and at 690 V it is 7.5 kA.

Does 3VA2325-5HK32-0AA0 have a trip indicator or undervoltage release?

No trip indicator, no undervoltage release, no communication function, and no ground-fault monitoring. The ETU340 electronic trip unit handles overcurrent protection only.

MPN
3VA2325-5HK32-0AA0