Siemens 3VA2325-5HL32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-5HL32-0AC0 SENTRON MCCB, 250A, 3-Pole, 121kA

MPN3VA2325-5HL32-0AC0

Siemens SENTRON 3VA series, molded case circuit breaker, 3VA2325-5HL32-0AC0, 250 A continuous, 3-pole, 121 kA at 415 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2325-5HL32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2325-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2325-5HL32-0AC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.37.5 W
3VA2325-5HL32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2325-5HL32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2325-5HL32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2325-5HL32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2325-5HL32-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA2325-5HL32-0AC0 is a 3-pole molded case circuit breaker rated for 250 A continuous current at 40 °C through 70 °C, making it a thermally stable choice for high-ambient panel environments without derating across that range. Breaking capacity hits 121 kA at 415 V and 440 V, with 187 kA available at 240 V — that's a serious SCCR for industrial distribution where fault current runs high on the secondary side of a large transformer. This is a line-protection design (not motor-protection pattern), so it tracks overload and short-circuit for feeder or main breaker duty.

Panel fit and physical integration

Dimensions: 248 mm height, 138 mm width, 110 mm depth. The 110 mm depth is the critical dimension for enclosure depth clearance — verify gland-plate and back-panel clearance against your enclosure's usable depth. The breaker ships with 2 auxiliary switches HQ as standard, so you get status feedback without ordering a separate aux block. No trip indicator, no undervoltage release, no auxiliary release on this variant.

With 121 kA at 415 V and 75.6 kA at 500 V, this MCCB can serve as a main or branch breaker in high-fault-current installations. The 7.5 kA at 690 V figure tells you it is not intended for 690 V distribution as a primary role — the arc-extinction capability drops off above 500 V. The continuous rating holds flat at 250 A across the full operating range — no thermal derating curve needed for ambient up to 70 °C.

MPN