The Siemens SENTRON 3VA2325-5HL32-0BC0 is a 3-pole molded case circuit breaker rated for 250 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed as the panel warms up. That flat thermal curve simplifies panel build: you don't have to oversize the frame or leave extra air around it for a conveyor zone or pump feeder. Breaking capacity hits 187 kA at 240 V and still holds 121 kA at 415/440 V, dropping to 7.5 kA at 690 V. For a 480 V distribution panel feeding motor control centers, the 121 kA figure gives you real SCCR headroom — coordination studies stay clean without cascading upstream.

Siemens 3VA2325-5HL32-0BC0 SENTRON MCCB, 250 A, 3-Pole
MPN3VA2325-5HL32-0BC0
Siemens SENTRON 3VA2325-5HL32-0BC0, molded case circuit breaker, 3-pole, 250 A continuous, 187 kA breaking capacity at 240 V, undervoltage release, 2 auxiliary switches HQ.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Basic switch (supplied) ref. | 3VA2325-5HL32-0AA0 |
| Integrated auxiliary / alarm switch ref. | 3VA9988-0AA12 |
| Parameter | Value |
|---|---|
| Number of poles | 3 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 250 A |
| Current at 45 °C | 250 A |
| Current at 50 °C | 250 A |
| Current at 55 °C | 250 A |
| Current at 60 °C | 250 A |
| Current at 65 °C | 250 A |
| Current at 70 °C | 250 A |
| Switching capacity class | M |
| Breaking capacity at 240 V | 187 kA |
| Breaking capacity at 415 V | 121 kA |
| Breaking capacity at 440 V | 121 kA |
| Breaking capacity at 500 V | 75.6 kA |
| Breaking capacity at 690 V | 7.5 kA |
| Power loss, max. | 40 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | ETU320 |
| Overcurrent protection function | LI |
| Ground-fault monitoring | Without |
| Grounding protection function | No |
| Parameter | Value |
|---|---|
| Main circuit connection type | on both sides nut keeper kit |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | Yes |
| Voltage trigger | No |
| Trip indicator | No |
| Communication function | No |
| Measurement function | No |
| Motor drive option | Yes |
| Auxiliary CO contacts | 2 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 20 000 |
| Height | 248 mm |
| Width | 138 mm |
| Depth | 110 mm |
| Height (in) | 9.76 in |
| Width (in) | 5.43 in |
| Depth (in) | 4.33 in |
Product details
Frequently asked questions
Does 3VA2325-5HL32-0BC0 include an undervoltage release?
Yes, it ships with an undervoltage release (UVR) and two auxiliary switches HQ as standard.
MPN
3VA2325-5HL32-0BC0