Skip to main content
Siemens 3VA2325-5HL32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-5HL32-0HC0 SENTRON MCCB, 250 A, 3-Pole, 187

MPN3VA2325-5HL32-0HC0

Siemens SENTRON 3VA2325-5HL32-0HC0, 3-pole molded case circuit breaker, 250 A continuous, interrupting 187 kA at 240 V, line-protection design with shunt trip and HQ auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-5HL32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2325-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2325-5HL32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.37.5 W

Protection & Trip Unit

3VA2325-5HL32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2325-5HL32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-5HL32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2325-5HL32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-5HL32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB is and where it fits

The Siemens SENTRON 3VA2325-5HL32-0HC0 is a 3-pole molded case circuit breaker rated for 250 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. It is designed for line protection in distribution panels and switchboards, with interrupting ratings that scale from 187 kA at 240 V down to 7.5 kA at 690 V, so it handles high-fault utility feeds and downstream sub-distribution alike. Built into a 138 mm wide, 248 mm tall, 110 mm deep frame, it occupies a standard MCCB footprint in a SENTRON panelboard.

Integration notes

Mounts in a standard SENTRON panelboard or standalone enclosure on a DIN rail or direct-mount plate. The 138 mm width fits a 3-pole MCCB cutout; the 110 mm depth leaves clearance for rear-connected busbars. The shunt trip (STL) allows remote tripping from an emergency-stop circuit or a PLC digital output — verify the coil voltage matches the control supply. The two HQ auxiliary switches provide status feedback (open/closed/tripped) to a PLC or indicator lamp. No communication function on this variant; it is a pure power breaker.

Frequently asked questions

Where can I buy the 3VA2325-5HL32-0HC0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the interrupting rating of the 3VA2325-5HL32-0HC0 at 240 V?

187 kA at 240 V, scaling down to 121 kA at 415 V / 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V.

Does the 3VA2325-5HL32-0HC0 include a shunt trip?

Yes, it is factory-fitted with a shunt trip (STL) and two HQ auxiliary switches.

MPN
3VA2325-5HL32-0HC0