Skip to main content
Siemens 3VA2325-5HL32-0KF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-5HL32-0KF0 Circuit Breaker, 250A, 55kA @ 415

MPN3VA2325-5HL32-0KF0

Siemens 3VA2 series, IEC frame 400, breaking capacity class M, Icu=55kA @ 415V, 3-pole, line protection ETU320, LI, In=250A, overload protection Ir=100A...250A, short-circuit protection Ii=1.5...12 x In, nut keeper kit, shunt trip (STL) 220-250V DC / 208-277V AC, 1 auxiliary switch HQ, 1 trip alarm switch HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

Panel-builder commissioning notes

The 3VA2325-5HL32-0KF0 is a current-production IEC frame 400 molded-case circuit breaker from the Siemens 3VA2 line, rated for 250 A continuous with an Icu of 55 kA at 415 V AC — that's the maximum fault current it can safely interrupt without damage, sized for high-fault industrial distribution panels where a standard 25 kA breaker would weld closed on a bolted fault. The ETU320 electronic trip unit provides LI (long-time and instantaneous) protection: overload pickup adjustable from 100 A to 250 A, and short-circuit pickup from 1.5× to 12× In, so you can coordinate selectively with downstream feeders without nuisance tripping on motor inrush.

DIN-rail integration and fill factor

Mounts on standard DIN rail in the enclosure; the nut keeper kit (included) prevents terminal hardware from backing off under vibration on a conveyor line or pump skid. The 3-pole footprint occupies three module widths — plan gland-plate knockouts accordingly when laying out a multi-breaker panel.

Shunt trip and auxiliary wiring

The factory-fitted shunt trip (STL) operates on 220–250 V DC or 208–277 V AC, letting you remote-trip the breaker from an E-stop or fire-alarm relay without a separate interposing contactor. One HQ auxiliary switch and one trip alarm switch are included for status feedback to the PLC or annunciator panel.

Frequently asked questions

What is the breaking capacity of this breaker?

The 3VA2325-5HL32-0KF0 has an Icu of 55 kA at 415 V AC, which is the maximum fault current it can safely interrupt without damage.

What does the ETU320 trip unit protect against?

The ETU320 provides LI protection: long-time (overload) adjustable from 100 A to 250 A, and instantaneous (short-circuit) adjustable from 1.5× to 12× In.

How do I get pricing and availability for the 3VA2325-5HL32-0KF0?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability confirmation.

Does this breaker include a shunt trip and auxiliary contacts?

Yes, it comes with a shunt trip (STL) rated 220–250 V DC / 208–277 V AC, one HQ auxiliary switch, and one trip alarm switch.

MPN
3VA2325-5HL32-0KF0