Skip to main content
Siemens 3VA2325-5HN32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-5HN32-0KL0 SENTRON MCCB, 250 A, 3-Pole, 187

MPN3VA2325-5HN32-0KL0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2325-5HN32-0KL0, 3-pole, 250 A continuous, 187 kA interrupting at 240 V AC, line protection design with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-5HN32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2325-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2325-5HN32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.37.5 W

Protection & Trip Unit

3VA2325-5HN32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2325-5HN32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-5HN32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2325-5HN32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-5HN32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Siemens 3VA2325-5HN32-0KL0 — 250 A MCCB for Line Protection

The Siemens 3VA2325-5HN32-0KL0 is a SENTRON 3VA2-series molded case circuit breaker (MCCB) rated for 250 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed until you exceed that. That 250 A holds at every 5 °C step from 40 up to 70 °C, so it's a straight drop-in for a warm panel without recalculating the thermal curve. Three-pole, line-protection design. Interrupting capacity hits 187 kA at 240 V AC, drops to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V. That 187 kA at 240 V puts it in the high-fault tier for North American 240 V delta or 277/480 V wye panels where the available fault current is stiff. The 121 kA at 415 V covers most European 400 V industrial distribution. This breaker ships with a shunt trip (STL) auxiliary release and a full complement of switching accessories: two auxiliary switches, one trip alarm switch, and one electrical alarm switch (HQ designation). The basic switch core is order code 3VA2325-5HN32-0AA0. A trip indicator and voltage trigger are both present. No undervoltage release, no ground-fault monitoring, no communication module on this variant.

Dimensions and Panel Fit

Footprint: 138 mm wide, 248 mm tall, 110 mm deep. That 110 mm depth is shallow enough for most 200 mm deep enclosures without a gland-plate conflict. The 138 mm width is the standard 3-pole MCCB pitch in the SENTRON 3VA2 family — lines up with busbar adapters and the mounting feet on the DIN-rail adapter plate. No special cutout needed if you're replacing an existing 3VA2 frame.

Frequently asked questions

What are the interrupting ratings for 3VA2325-5HN32-0KL0 at common voltages?

187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V. The 187 kA at 240 V covers high-fault North American panels; the 121 kA at 415 V suits European 400 V distribution.

Does 3VA2325-5HN32-0KL0 require derating at elevated ambient temperatures?

No derating needed from 40 °C through 70 °C — the 250 A continuous rating holds at every 5 °C step (–). Above 70 °C you would need to consult the thermal derating curve, but for most industrial enclosures that's not a concern.

What auxiliary switches and releases come with 3VA2325-5HN32-0KL0?

It includes two auxiliary switches, one trip alarm switch, one electrical alarm switch (HQ), and a shunt trip (STL) release. No undervoltage release or ground-fault module on this variant. The basic switch core is order code 3VA2325-5HN32-0AA0.

How do I get current pricing and availability for 3VA2325-5HN32-0KL0?

Submit an RFQ with your target quantity and ship window. Availability and current pricing are confirmed at quote time through independent distribution — no published stock count or lead-time figure is maintained on this listing.

MPN
3VA2325-5HN32-0KL0