Siemens 3VA2325-5MN32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-5MN32-0KL0 SENTRON MCCB, 250A, 3-Pole, Motor

MPN3VA2325-5MN32-0KL0

Siemens SENTRON 3VA2325-5MN32-0KL0, molded case circuit breaker, 3-pole, 250 A, motor protection design, 187 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-5MN32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2325-5MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2325-5MN32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.37.5 W

Protection & Trip Unit

3VA2325-5MN32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2325-5MN32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-5MN32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2325-5MN32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-5MN32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Siemens 3VA2325-5MN32-0KL0 — 250 A Motor Protection MCCB

The Siemens 3VA2325-5MN32-0KL0 is a SENTRON molded case circuit breaker (MCCB) designed specifically for motor protection, with a 250 A rating held flat across the full 40 °C to 70 °C ambient range — no derating needed as the panel warms up. Three-pole construction with integrated phase failure detection, meaning it catches a lost phase on the line side and trips before single-phasing damages the motor windings. Breaking capacity runs 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 7.5 kA at 690 V — the 415 V figure is the one that governs most European 400 V distribution panels, and 121 kA gives generous headroom above typical 50 kA or 65 kA fault levels.

Motor Protection Specifics

The breaker is designated as motor protection design, which means its trip curve and thermal memory are tuned for motor inrush and overload profiles — not the same as a standard distribution MCCB. Maximum power loss is 37.5 W, relevant for enclosure thermal calculations when the breaker is enclosed alongside other heat sources. Operating temperature range spans -25 °C to 70 °C; storage range is -40 °C to 80 °C.

Auxiliary and Release Configuration

Factory-fitted with two auxiliary switches, one trip alarm switch, and one electrical alarm switch HQ — the HQ designation indicates high-qualified contacts rated for low-energy signal circuits typical of PLC inputs. Includes a shunt trip release (STL) for remote tripping via an emergency-stop or safety relay circuit. The basic switch variant is order code 3VA2325-5MN32-0AA0, which is the core switching mechanism this assembly builds on. No undervoltage release fitted; no ground-fault monitoring module included — those are separate accessory additions if needed.

Frequently asked questions

Does 3VA2325-5MN32-0KL0 include phase failure protection?

Yes, it has integrated phase failure detection that trips before single-phasing damages motor windings.

What auxiliary switches are fitted on 3VA2325-5MN32-0KL0?

Two auxiliary switches, one trip alarm switch, and one electrical alarm switch HQ, plus a shunt trip release for remote tripping.

MPN
3VA2325-5MN32-0KL0