Skip to main content
Siemens 3VA2325-6HL32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2325-6HL32-0DA0 SENTRON MCCB, 250 A, 3-Pole, 110

MPN3VA2325-6HL32-0DA0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2325-6HL32-0DA0, 3-pole, 250 A, 242 kA at 240 V, line protection, undervoltage release, depth 110 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2325-6HL32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2325-6HL32-0AA0
3VA2325-6HL32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.40 W
3VA2325-6HL32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2325-6HL32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2325-6HL32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2325-6HL32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2325-6HL32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

It carries a 242 kA interrupting capacity at 240 V, dropping to 187 kA at 415 V and 440 V, then 121 kA at 500 V, and 7.5 kA at 690 V — the steep fall at 690 V tells you this breaker is optimized for 240–500 V distribution, not 690 V motor circuits.

Standard DIN-rail or screw-mount pattern matches the 3VA2 family, so a swap from a 3VA2 of the same frame size is direct.

Frequently asked questions

Where can I buy 3VA2325-6HL32-0DA0 and how do I get a price?

We source this part to order against an RFQ; availability and current pricing are confirmed at quote time through our industrial-automation distribution channel.

What is 3VA2325-6HL32-0DA0's listed depth?

The depth is 110 mm (4.33 in).

What compliance documentation does this breaker carry?

As a SENTRON series MCCB, it is designed to meet IEC 60947-2 and UL 489 standards; RoHS and REACH declarations are available from the manufacturer on request.

MPN