Skip to main content
Siemens 3VA2325-6HL32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2325-6HL32-0JC0 MCCB, 250 A, 3-pole, 242

MPN3VA2325-6HL32-0JC0

Siemens SENTRON molded case circuit breaker, 3VA2325-6HL32-0JC0, line protection, 3-pole, 250 A continuous, breaking capacity 242 kA at 240 V, with shunt trip and 2 auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2325-6HL32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2325-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2325-6HL32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C250 A
Current at 60 °C250 A
Current at 65 °C250 A
Current at 70 °C250 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.37.5 W

Protection & Trip Unit

3VA2325-6HL32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2325-6HL32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2325-6HL32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2325-6HL32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2325-6HL32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB delivers on the line side

The Siemens SENTRON 3VA2325-6HL32-0JC0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Breaking capacity runs 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 7.5 kA at 690 V, so it handles high-fault utility feeds or transformer secondaries without cascading upstream. The frame is sized for line protection, not motor or generator duty.

Integration and auxiliary hardware

This variant ships with a factory-fitted shunt trip (STL) release and two auxiliary switches (HQ design), so it integrates directly into emergency-stop or remote-trip circuits without field wiring a separate undervoltage release. The basic switch supplied is 3VA2325-6HL32-0AA0. Dimensions are 248 mm high, 138 mm wide, 110 mm deep — fits standard MCCB panel cutouts for the SENTRON 3VA frame family.

MPN
3VA2325-6HL32-0JC0